The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Biodegradable Untethered Magnetic Hydrogel Milli‐Grippers
Open accessAbstract
Small‐scale magnetic soft‐bodied robots based on biocompatible and biodegradable materials are essential for their potential high‐impact minimally invasive medical applications inside the human body. Therefore, a strategy for fully biodegradable untethered soft millirobots with encoded 3D magnetic anisotropy for their static or dynamic shape programming is presented. Such a robot body is comprised of a porcine extracellular matrix‐derived collagen‐based hydrogel network with embedded superparamagnetic iron oxide nanoparticles (SPIONs). 3D magnetization programming inside the hydrogel body is achieved by directionally self‐assembled SPION chains using an external permanent magnet. As a proof‐of‐concept demonstration, a hydrogel milli‐gripper that can undergo flexible and reversible shape deformations inside glycerol and biologically relevant liquid media is presented. The gripper can perform cargo grabbing, transportation by rolling, and release by controlling magnetic field inputs. These milli‐grippers can be completely degraded by the matrix metalloproteinase‐2 enzyme in physiologically relevant concentrations. Furthermore, biocompatibility tests using human umbilical cord vein endothelial cells with the degradation products of the grippers demonstrate no acute toxicity. The approach offers a facile fabrication strategy for designing biocompatible and biodegradable soft robots using nanocomposite materials with programmable 3D magnetic anisotropy toward future medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double-slit photoelectron interference in strong-field ionization of the neon dimer
Kunitski, M., Eicke, N., Huber, P., Köhler, J., Zeller, S., Voigtsberger, J., Schlott, N., Henrichs, K., Sann, H., Trinter, F., et al. (2019) · Nature Communications · doi:10.1038/s41467-018-07882-8 · Cited by 8,162
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Cited by
Soft actuators for real-world applications
Li, M., Pal, A., Aghakhani, A., Pena-Francesch, A., & Sitti, M. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00389-7 · Cited by 880
Self-citationMagnetic Soft Materials and Robots
Kim, Y., & Zhao, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00481 · Cited by 873
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
4D Printing for Biomedical Applications
Yarali, E., Mirzaali, M. J., Ghalayaniesfahani, A., Accardo, A., Diaz‐Payno, P. J., & Zadpoor, A. A. (2024) · Advanced Materials · doi:10.1002/adma.202402301 · Cited by 257
Metadata
- Authors
- Goudu, S. R., Yasa, I. C., Hu, X., Ceylan, H., Hu, W., & Sitti, M.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2020-09-15
- Volume
- 30
- Issue
- 50
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W3087565571
- Cited by
- 207
- References
- 2
- FWCI
- 26.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biodegradable Untethered Magnetic Hydrogel Milli‐Grippers. https://app.cochat.ai/papers/10.1002/adfm.202004975
- The paper
- Goudu, S. R., Yasa, I. C., Hu, X., Ceylan, H., Hu, W., & Sitti, M. (2020). Biodegradable Untethered Magnetic Hydrogel Milli‐Grippers. Advanced Functional Materials. https://doi.org/10.1002/adfm.202004975
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.