The DOI matches its Crossref record; 447 of the 448 references it cites were found in a registry or an index.
Powering Implantable and Ingestible Electronics
Open accessAbstract
Implantable and ingestible biomedical electronic devices can be useful tools for detecting physiological and pathophysiological signals, and providing treatments that cannot be done externally. However, one major challenge in the development of these devices is the limited lifetime of their power sources. The state-of-the-art of powering technologies for implantable and ingestible electronics is reviewed here. The structure and power requirements of implantable and ingestible biomedical electronics are described to guide the development of powering technologies. These powering technologies include novel batteries that can be used as both power sources and for energy storage, devices that can harvest energy from the human body, and devices that can receive and operate with energy transferred from exogenous sources. Furthermore, potential sources of mechanical, chemical, and electromagnetic energy present around common target locations of implantable and ingestible electronics are thoroughly analyzed; energy harvesting and transfer methods befitting each energy source are also discussed. Developing power sources that are safe, compact, and have high volumetric energy densities is essential for realizing long-term in-body biomedical electronics and for enabling a new era of personalized healthcare.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These conventional batteries, although energy dense, consume over half of the implant’s total volume and have limited duration of power supply (Yang et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Yang et al., 2021
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The limitation in available power supply options poses a significant challenge in powering brain implants, often restricting the device’s key features such as power density, including its diagnostic and therapeutic capabilities, operational lifespan, and duty cycle (Yang et al., 2021).”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Yang et al., 2021
The cited source says what the claim attributes to it.
In the citing paper
“A significant advancement in this area has been the development of solid-state electrolytes, allowing the thickness of these microbatteries to be reduced to mere micrometers.”
From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Yang et al., 2021
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Items 401–447 of 447
Methods for Powering Bioelectronic Microdevices
Lee, P. M., Xiong, Z., & Ho, J. S. (2018) · Bioelectronics in Medicine · doi:10.2217/bem-2018-0005 · Cited by 23
Intestinal obstruction by capsule endoscopy in a patient with radiation enteritis.
Rogers, A. M., Kuperman, E. F., Puleo, F. J., & Shope, T. R. (2008) · PubMed Central · Cited by 22
Capsule Endoscopy: A Cause of Late Small Bowel Obstruction and Perforation
Skovsen, A. P., Burcharth, J., & Burgdorf, S. K. (2013) · Case Reports in Surgery · doi:10.1155/2013/458108 · Cited by 21
Study of power generating implantable electrodes
Massie, H., Racine, P., Pasker, R., Hahn, A. W., & Sun, H. H. (1968) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474289 · Cited by 21
Development of Electroplated Magnesium Microstructures for Biodegradable Devices and Energy Sources
Tsang, M., Armutlulu, A., Herrault, F., Shafer, R. H., Allen, S. A. B., & Allen, M. G. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2360201 · Cited by 21
A MEMS-enabled biodegradable battery for powering transient implantable devices
Tsang, M., Armutlulu, A., Martinez, A. W., Herrault, F., Allen, S. A. B., & Allen, M. G. (2014) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2014.6765650 · Cited by 20
High-resolution manometry for the evaluation of gastric motility
Herbella, F. A. M., Aprile, L. R. O., & Patti, M. G. (2014) · Updates in Surgery · doi:10.1007/s13304-014-0261-4 · Cited by 20
Automatic detection of colonoscopic anomalies using capsule endoscopy
Gueye, L., Yayilgan, S. Y., Cheikh, F. A., & Balasingham, I. (2015) · Proceedings - International Conference on Image Processing · doi:10.1109/icip.2015.7350962 · Cited by 20
A Near-Infrared Optomechanical Intracranial Pressure Microsensor
Ghannad‐Rezaie, M., Yang, L. J. ‐., Garton, H. J. L., & Chronis, N. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2171322 · Cited by 19
Electrical conduction in acrylonitrile/methylacrylate copolymer films
von Berlepsch, H., Pinnow, M., & Stark, W. (1989) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/22/8/019 · Cited by 19
Nanodevice Arrays for Peripheral Nerve Fascicle Activation Using Ultrasound Energy-Harvesting
Donohoe, M., Jennings, B., Jornet, J. M., & Balasubramaniam, S. (2017) · IEEE Transactions on Nanotechnology · doi:10.1109/tnano.2017.2723658 · Cited by 19
An optimal controller for an electric ventricular-assist device: Theory, implementation, and testing
Klute, G. K., Tasch, U., & Geselowitz, D. B. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.126612 · Cited by 18
In-situ Cutting of Graphene into Short Nanoribbons with Applications to Ni-Zn Batteries
Cui, C., Li, M., & Zhang, X. (2018) · Scientific Reports · doi:10.1038/s41598-018-23944-9 · Cited by 18
Bawiec, C. R., N’Djin, W. A., Bouchoux, G., Sénégond, N., Guillen, N., & Chapelon, J. (2018) · IRBM · doi:10.1016/j.irbm.2018.09.001 · Cited by 18
Biofluid Activated Microbattery for Disposable Microsystems
Garay, E. F., & Bashirullah, R. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2317177 · Cited by 17
ENERGY TRANSFER FOR IMPLANTABLE ELECTRONICS IN THE ELECTROMAGNETIC MIDFIELD (Invited Paper)
Ho, J. S., & Poon, A. S. Y. (2014) · Electromagnetic waves · doi:10.2528/pier14070603 · Cited by 16
Tseung, A. C. C., King, W. J., & Wan, B. Y. C. (1971) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474813 · Cited by 16
Graff, K. F. (2014) · Elsevier eBooks · doi:10.1016/b978-1-78242-028-6.00006-5 · Cited by 16
Kim, S. H., Yu, C., & ISHIYAMA, K. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2015.2436910 · Cited by 14
Xin, L., Liao, Z., Du, Y., Jiang, Y., & Li, Z. (2012) · Journal of Interventional Gastroenterology · doi:10.4161/jig.20128 · Cited by 13
Beilke, M. C., Klotzbach, T. L., Treu, B. L., Sokic‐Lazic, D., Wildrick, J., Amend, E. R., Gebhart, L. M., Arechederra, R. L., Germain, M. N., Moehlenbrock, M. J., et al. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374713-6.00005-6 · Cited by 13
Jéhannin, P., Craughwell, M., Omarjee, L., Donnelly, A., Jaquinandi, V., Mahé, G., & Faucheur, A. L. (2020) · Vascular Medicine · doi:10.1177/1358863x20902272 · Cited by 12
Arriagada, A., Jurkov, A. S., Neshev, E., Muench, G., Mintchev, M. P., & Andrews, C. N. (2010) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2010.01636.x · Cited by 11
Finite-element analysis of flow induced by contractions like those of the intestine
Stavitsky, D., Macagno, E. O., & Christensen, J. C. (1981) · Journal of Biomechanics · doi:10.1016/0021-9290(81)90025-7 · Cited by 11
Hyperthermia Therapy for Cancer
Stauffer, P. R., & Paulides, M. M. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-53632-7.01009-1 · Cited by 11
Establishment of boundaries for near-field, fresnel and Fraunhofer-field regions
Amin, S., Ahmed, B., Amin, M., Abbasi, M. I., Elahi, A., & Aftab, U. (2017) · Asia-Pacific Microwave Conference (APMC) · doi:10.1109/apmc.2017.8251376 · Cited by 11
Bulk-Type All-Solid-State Lithium Secondary Battery with Li2S-P2S5 Thin-Film Separator
Sakuda, A., Hayashi, A., Ohtomo, T., Hama, S., & Tatsumisago, M. (2012) · Electrochemistry · doi:10.5796/electrochemistry.80.839 · Cited by 10
Triboelectricity and construction of power generators based on it
MOLNAR, O. (2018) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2018.01.41 · Cited by 10
The Implantable Peritoneal Pump—A Patient's Perspective
Witkowski, C. J., & Saudek, C. D. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200423 · Cited by 9
Successful Retrieval of a Retained Capsule Endoscope with Single Incision Laparoscopic Surgery
Tashiro, Y., Kawai, M., Takehara, K., Munakata, S., Ishiyama, S., Sugimoto, K., Takahashi, M., Kojima, Y., Goto, M., Tomiki, Y., et al. (2014) · Case Reports in Gastroenterology · doi:10.1159/000364821 · Cited by 9
Musical FAVORS: Reintroducing music to adult cochlear implant users
Plant, G. (2015) · Cochlear Implants International · doi:10.1179/1467010015z.000000000271 · Cited by 9
Hunter, J., & Rawlings‐Anderson, K. (2008) · Nursing Standard · doi:10.7748/ns2008.06.22.41.41.c6576 · Cited by 9
Bioelectrical energy by reduction of tissue oxygen.
Satinsky, V. P., Cassel, J. C., & Salkind, A. J. (1971) · PubMed · Cited by 8
What is the mechanism behind biological ferroelectricity?
Zelisko, M., Li, J., & Sharma, P. (2015) · Extreme Mechanics Letters · doi:10.1016/j.eml.2015.07.001 · Cited by 6
Burianová, L., Hana, P., Tyagur, Y. I., & Kułek, J. (1999) · Ferroelectrics · doi:10.1080/00150199908210547 · Cited by 6
Improvements in biogalvanic energy sources
Roy, O. Z., & Wehnert, R. W. (1974) · Medical & Biological Engineering & Computing · doi:10.1007/bf02629834 · Cited by 6
ANALYTICAL CHEMISTRY DIVISION COMMISSION ON ELECTROANALYTICAL CHEMISTRY
(1976) · Elsevier eBooks · doi:10.1016/b978-0-08-021226-5.50002-2 · Cited by 6
Elements of the IVth group and IV-IV compounds
Madelung, O. (2004) · Springer eBooks · doi:10.1007/978-3-642-18865-7_2 · Cited by 5
Calorimetric Study of the Calcium / Sr ( AlCl4 ) 2 ‐ SOCl2 Battery
Cohen, R. A., Lavi, Y. B., & Peled, E. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2087003 · Cited by 5
MEMS based piezoelectric ultrasonic energy harvester for self-powered under-water applications
Shi, Q., Wang, T., Kobayashi, T., & Lee, C. (2016) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2016.7421866 · Cited by 5
Gowda, S. (2010) · Jaypee Brothers Medical Publishers (P) Ltd. eBooks · doi:10.5005/jp/books/10401_15 · Cited by 4
Atlas of High-Resolution Manometry, Impedance, and pH Monitoring
Moosavi, S., Rezaie, A. R., Pimentel, M., & Pichetshote, N. (2019) · Springer eBooks · doi:10.1007/978-3-030-27241-8 · Cited by 4
A 0.9-V 96-/spl mu/W Digital Hearing Aid Chip with Heterogeneous S-D DAC
Kim, S., Cho, N., Song, S.-J., Kim, D., Kim, K., & Yoo, H. (2006) · Symposium on VLSI Circuits · doi:10.1109/vlsic.2006.1705309 · Cited by 3
Sensitivity and directivity measurement of ultrasonic transducer with polymer-powder matching layer
Fazlyyyakhmatov, M. G. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1038/1/012109 · Cited by 3
Newnham, J. (1972) · BMJ · doi:10.1136/bmj.1.5794.250 · Cited by 3
Kaiplavil, S., Rivens, I., & ter Haar, G. (2013) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2013.2708 · Cited by 2
Oral Exposure of a Child to a Lithium Ion Battery.
Townsend, J. A., & Curran, R. (2016) · PubMed · Cited by 1
Flagged first, then by citations
1 of the 448 references couldn’t be matched to a known paper.
Research works printed but not linked: 27
- Gueye L., 2015, 2015 IEEE Int. Conf. on Image Processing (ICIP), 1061
- 10.2741/e729 · DOI
- Tarascon J.‐M., 2011, Materials for Sustainable Energy: A Collection of Peer‐Reviewed Research and Review Articles from Nature Publishing Group, 171
- Aquilina O., 2006, Images Paediatr. Cardiol., 8, 17
- Xiao Z., 2015, IEEE J. Biomed. Health Inf., 19, 910
- Townsend J. A., 2016, J. Dent. Child., 83, 42
- Tsang M., 2014, 2014 IEEE 27th Int. Con. on Micro Electro Mechanical Systems (MEMS), 358
- Rogers A. M., 2008, J. Sci. Lett., 12, 85
- 2019, Marketing Clearance of Diagnostic Ultrasound Systems and Transducers
- Curie J., 1880, Bull. Mineral., 3, 90
- 10.1109/TDEI.1995.8881940 · DOI
- Valone T., 1998, The Homopolar Handbook: A Definitive Guide to Faraday Disk and N‐Machine Technologies
- Romero E., 2009, 2009 Ann. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, 2752
- Kim S. H., 2016, IEEE/ASME Trans. Mechatron., 21, 122
- Jonsson M., 2014, Exp. Clin. Cardiol., 20, 2000
- Brandstaeter S., 2019, Ges. Angew. Math. Mech., 42, e201900001
- Drake R. F., 1970, Trans.—Am. Soc. Artif. Inter. Organs, 16, 199
- Ichi S. El, 2014, IECBES 2014, Conference Proceedings—2014 IEEE Conference on Biomedical Engineering and Sciences: “Miri, Where Engineering in Medicine and Biology and Humanity Meet,”, 51
- P.Malachesky G.Holleck F.McGovern R.Devarakonda Proceedings of the 7th Intersociety Energy Conversion Engineering Conference San Diego California USA1972 pp.727–732.
- RoY O., 1966, Electronics, 39, 105
- Satinsky V. P., 1971, J. Assoc. Adv. Med. Instrum., 5, 3
- Tutuian R., 2006, GI Motility online
- Justin G. A., 2004, The 26th Annu. Int. Conf. of the IEEE Engineering in Medicine and Biology Society, 4096
- Mazzilli F., 2012, 2012 IEEE Int. Symp. on Circuits and Systems (ISCAS), 2865
- Institute of Electrical and Electronics Engineers IEEE standard for safety levels with respect to human exposure to radio frequency electromagnetic fields 3 kHz to 300 GHz Institute of Electrical and Electronics Engineers New York 2006.
- D.Seo J. M.Carmena J. M.Rabaey E.Alon M. M.Maharbiz (preprint)arXiv arXiv:1307.2196 v1 submitted: July2013. · arXiv
- Wang J., 2017, 2017 IEEE Int. Ultrasonics Symp. (IUS), 1
Cited by
Sorted by citations
Advanced Energy Harvesters and Energy Storage for Powering Wearable and Implantable Medical Devices
Gao, Z., Zhou, Y., Zhang, J., Foroughi, J., Peng, S., Baughman, R. H., Wang, Z. L., & Wang, C. (2024) · Advanced Materials · doi:10.1002/adma.202404492 · Cited by 250
A Tissue‐Like Soft All‐Hydrogel Battery
Ye, T., Wang, J., Jiao, Y., Li, L., He, E., Wang, L., Li, Y., Yun, Y., Li, D., Jiang, L., et al. (2021) · Advanced Materials · doi:10.1002/adma.202105120 · Cited by 184
Liu, Y., Zhou, H., Zhou, W., Meng, S., Cheng, Q., Liu, Z., & Kong, T. (2021) · Advanced Energy Materials · doi:10.1002/aenm.202101329 · Cited by 181
Electroconductive, Adhesive, Non‐Swelling, and Viscoelastic Hydrogels for Bioelectronics
Han, I. K., Song, K., Jung, S., Jo, Y., Kwon, J., Chung, T., Yoo, S., Jang, J., Kim, Y., Hwang, D. S., et al. (2022) · Advanced Materials · doi:10.1002/adma.202203431 · Cited by 170
Soft Fiber Electronics Based on Semiconducting Polymer
Sun, F., Jiang, H., Wang, H., Zhong, Y., Xu, Y., Xing, Y., Yu, M., Feng, L., Tang, Z., Liu, J., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00720 · Cited by 167
Metadata
- Authors
- Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G.
- Affiliations
- Koch Institute for Integrative Cancer Research At MIT (US)
- Koch Institute for Integrative Cancer Research Massachusetts Institute of Technology Cambridge MA 02139 USA
- Brigham and Women's Hospital (US)
- Corresponding author
- Traverso, Giovanni
- ORCID
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2021-02-04
- Volume
- 31
- Issue
- 44
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- PMC
- PMC8553224
- OpenAlex
- W3126551253
- Cited by
- 183
- References
- 448
- Citations by year
- 2026: 34 · 2025: 52 · 2024: 33 · 2023: 31 · 2022: 22 · 2021: 11
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Advanced Functional Materials (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Research Online (University of Wollongong) (submittedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
- Figshare (submittedVersion, cc-by)
- Funders
- National Institutes of Health
- Department of Mechanical Engineering, College of Engineering, Michigan State University
- Massachusetts Institute of Technology
- Kwanjeong Educational Foundation (19AmB32G)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- implantable electronics, medical electronics, power sources, energy harvesting, energy storage, batteries, wireless power transfer, volumetric energy density, personalized healthcare
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review