The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly Stretchable, Ultra‐Soft, and Fast Self‐Healable Conductive Hydrogels Based on Polyaniline Nanoparticles for Sensitive Flexible Sensors
Abstract
Herein, novel conductive composite hydrogels are developed with high stretchability, ultra‐softness, excellent conductivity, and good self‐healing ability. The hydrogels are formed in the water/glycerol binary solvent system, in which the polyaniline nanoparticles (PANI‐NPs) are incorporated into the poly(poly(ethylene glycol) methacrylate‐co‐acrylic acid) (P(PEG‐co‐AA)) scaffolds via the dynamically electrostatic interactions and hydrogen bonds. The PANI‐NPs serve as conductive fillers to assign conductivity to the hydrogel, while the enhanced interfacial interactions between the PANI‐NPs and P(PEG‐co‐AA) matrix endow the hydrogel with high stretchability (>1000%), low modulus (≈6 kPa), excellent elasticity (η = 0.07, energy loss coefficient at 500% strain), and fast self‐healing ability (93.3% after 10 mins). Particularly, the desirable anti‐freezing property is achieved by introducing a binary solvent system. The composite hydrogel‐based sensors are proposed, with the states‐independent properties, low detection limit (0.5% strain and 25 Pa), highly linear dependence, and excellent anti‐fatigue performance (>1000 cycles). In addition, during the practical wearable sensing tests, various external stimulus and human motions can be detected, including speaking, writing, joint movement, or even small water droplets, indicating the potential applications for the next generation of epidermal sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rong, Q., Lei, W., Chen, L., Yin, Y., Zhou, J., & Liu, M. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201708614 · Cited by 733
Wang, M., Luo, Y., Wang, T., Wan, C., Pan, L., Pan, S., He, K., Neo, A., & Chen, X. (2021) · Advanced Materials · doi:10.1002/adma.202003014 · Cited by 451
Cited by
A self-healing electrically conductive organogel composite
Zhao, Y., Ohm, Y., Liao, J., Luo, Y., Cheng, H.-Y., Won, P., Roberts, P., Carneiro, M. R., Islam, M. F., Ahn, J. H., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-00932-0 · Cited by 292
Conductive polymer based hydrogels and their application in wearable sensors: a review
Liu, D., Huyan, C., Wang, Z., Guo, Z., Zhang, X., Torun, H., Mulvihill, D., Xu, B. B., & Chen, F. (2023) · Materials Horizons · doi:10.1039/d3mh00056g · Cited by 282
Self-citationToward Efficient Thermoelectric Materials and Devices: Advances, Challenges, and Opportunities
Shi, X.-L., Li, N.-H., Li, M., & Chen, Z.-G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00060 · Cited by 260
A Review of Conductive Hydrogel‐Based Wearable Temperature Sensors
Mo, F., Zhou, P., Lin, S., Zhong, J., & Wang, Y. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401503 · Cited by 187
Self-citation
Metadata
- Authors
- Yu, X., Zhang, H., Wang, Y., Fan, X., Li, Z., Zhang, X., & Liu, T.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2022-06
- Volume
- 32
- Issue
- 33
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4281668850
- Cited by
- 239
- References
- 2
- FWCI
- 12.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.