Phase Change Materials for Life Science Applications
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Phase change materials (PCMs) are a class of thermo‐responsive materials that can be utilized to trigger a phase transition which gives them thermal energy storage capacity. Any material with a high heat of fusion is referred to as a PCM that is able to provide cutting‐edge thermal storage. PCMs are commercially used in many applications like textile industry, coating, and cold storage typically for heat control. These intriguing substances have recently been rediscovered and employed in a broad range of life science applications, including biological, human body, biomedical, pharmaceutical, food, and agricultural applications. Benefiting from the changes in physicochemical properties during the phase transition makes PCMs also functional for barcoding, detection, and storage. Paraffin wax and polyethylene glycol are the most commonly studied PCMs due to their low toxicity, biocompatibility, high thermal stability, high latent enthalpy, relatively wide transition temperature range, and ease of chemical modification. Current challenges in employing PCMs for life science applications include biosafety and/or engineering difficulties. The focus of this review article is on the life science applications, evaluation, and safety aspects of PCMs. Herein, the advances and the potential of employing PCMs as a versatile platform for various types of life science applications are highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review on thermal energy storage with phase change materials and applications
Sharma, A., Tyagi, V. V., Chen, C. R., & Buddhi, D. (2009) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2007.10.005 · Cited by 5,936
Mohamed, S. A., Al-Sulaiman, F. A., Ibrahim, N. I., Zahir, M. H., Al-Ahmed, A., Saidur, R., Yılbaş, B. S., & Sahin, A. Z. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.12.012 · Cited by 759
Emerging Applications of Phase‐Change Materials (PCMs): Teaching an Old Dog New Tricks
Hyun, D. C., Levinson, N. S., Jeong, U., & Xia, Y. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201305201 · Cited by 363
Micro/nano-encapsulated phase change materials (PCMs) as emerging materials for the food industry
Alehosseini, E., & Jafari, S. M. (2019) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2019.07.003 · Cited by 242
Phase Change Materials for Application in Energy-Efficient Buildings
Jelle, B. P., & Kalnæs, S. E. (2017) · Cost-Effective Energy Efficient Building Retrofitting · doi:10.1016/b978-0-08-101128-7.00003-4 · Cited by 90
Metadata
- Authors
- Zare, M., & Mikkonen, K. S.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2023-01-25
- Volume
- 33
- Issue
- 12
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4319791614
- Cited by
- 229
- References
- 5
- FWCI
- 22.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.