The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
MXene Functionalized, Highly Breathable and Sensitive Pressure Sensors with Multi‐Layered Porous Structure
Abstract
Breathable, flexible, and highly sensitive pressure sensors have drawn increasing attention due to their potential in wearable electronics for body‐motion monitoring, human‐machine interfaces, etc. However, current pressure sensors are usually assembled with polymer substrates or encapsulation layers, thus causing discomfort during wearing (i.e., low air/vapor permeability, mechanical mismatch) and restricting their applications. A breathable and flexible pressure sensor is reported with nonwoven fabrics as both the electrode (printed with MXene interdigitated electrode) and sensing (coated with MXene/silver nanowires) layers via a scalable screen‐printing approach. Benefiting from the multi‐layered porous structure, the sensor demonstrates good air permeability with high sensitivity (770.86–1434.89 kPa−1), a wide sensing range (0–100 kPa), fast response/recovery time (70/81 ms), and low detection limit (≈1 Pa). Particularly, this sensor can detect full‐scale human motion (i.e., small‐scale pulse beating and large‐scale walking/running) with high sensitivity, excellent cycling stability, and puncture resistance. Additionally, the sensing layer of the pressure sensor also displays superior sensitivity to humidity changes, which is verified by successfully monitoring human breathing and spoken words while wearing a sensor‐embedded mask. Given the outstanding features, this breathable sensor shows promise in the wearable electronic field for body health monitoring, sports activity detection, and disease diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Jia, J., Huang, G., Deng, J., & Pan, K. (2019) · Nanoscale · doi:10.1039/c8nr08503j · Cited by 172
Cited by
Materials-Driven Soft Wearable Bioelectronics for Connected Healthcare
Gong, S., Lu, Y., Yin, J., Levin, A., & Cheng, W. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00502 · Cited by 411
Metadata
- Authors
- Zheng, X., Zhang, S., Zhou, M., Lu, H., Guo, S., Zhang, Y., Li, C., & Tan, S. C.
- Venue
- Advanced Functional Materials
- Publisher
- Wiley
- Published
- 2023-03-17
- Volume
- 33
- Issue
- 19
- ISSN
- 1616-301X (ISSN-L)
- 1616-3028
- OpenAlex
- W4327716487
- Cited by
- 234
- References
- 3
- FWCI
- 17.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.