CoChat

Conjugated Polymer Amplified Far‐Red/Near‐Infrared Fluorescence from Nanoparticles with Aggregation‐Induced Emission Characteristics for Targeted In Vivo Imaging

Open access
Ding, Dan, Li, Kai, Qin, Wei, Zhan, Ruoyu, Hu, Yong, Liu, Jianzhao, Tang, Ben Zhong, Liu, Bin · 2013 · Advanced Healthcare Materials
Cited by 116

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Fluorescence‐amplified far‐red/near‐infrared (FR/NIR) nanoparticles (NPs) are synthesized by co‐encapsulation of conjugated polymer donor (poly[9,9‐bis(2‐(2‐(2‐methoxyethoxy)ethoxy)ethyl)fluorenyldivinylene]; PFV) and a fluorogen acceptor (2‐(2,6‐bis((E)‐4‐(phenyl(4′‐(1,2,2‐triphenylvinyl)‐[1,1′‐biphenyl]‐4‐yl)amino)styryl)‐4 H‐pyran‐4‐ylidene)malononitrile; TPE‐TPA‐DCM) with aggregation‐induced emission (AIE) characteristics using biocompatible bovine serum albumin (BSA) as the encapsulation matrix. The good spectral overlap and close proximity between PFV and TPE‐TPA‐DCM in BSA NPs result in a 5.3‐fold amplified TPE‐TPA‐DCM emission signal via fluorescence resonance energy transfer (FRET). The obtained PFV/TPE‐TPA‐DCM co‐loaded BSA NPs are spherical in shape with a large Stokes shift of ∼223 nm and low cytotoxicity. The BSA matrix allows further functionalization with arginine‐glycine‐aspartic acid (RGD) peptide to yield fluorescent probes for specific recognition of integrin receptor‐overexpressed cancer cells. The advantage of PFV amplified FR/NIR signal from TPE‐TPA‐DCM is further demonstrated in cellular and in vivo imaging using HT‐29 colon cancer cells and a murine hepatoma H 22 tumor‐bearing mouse model, respectively. The high FR/NIR fluorescence and specific cancer targeting ability by RGD surface functionalization make the PFV/TPE‐TPA‐DCM co‐loaded BSA‐RGD NPs a unique FR/NIR fluorescent probe for cellular imaging and in vivo tumor diagnosis in a high contrast and selective manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adhm.201200243

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 116

Metadata

Authors
Ding, D., Li, K., Qin, W., Zhan, R., Hu, Y., Liu, J., Tang, B. Z., & Liu, B.
Venue
Advanced Healthcare Materials
Publisher
Wiley
Published
2012-11-26
Volume
2
Issue
3
Pages
500-507
ISSN
  • 2192-2640 (ISSN-L)
  • 2192-2659
OpenAlex
W1982110547
Cited by
116
References
3
FWCI
5.21
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conjugated Polymer Amplified Far‐Red/Near‐Infrared Fluorescence from Nanoparticles with Aggregation‐Induced Emission Characteristics for Targeted In Vivo Imaging. https://app.cochat.ai/papers/10.1002/adhm.201200243
The paper
Ding, D., Li, K., Qin, W., Zhan, R., Hu, Y., Liu, J., Tang, B. Z., & Liu, B. (2013). Conjugated Polymer Amplified Far‐Red/Near‐Infrared Fluorescence from Nanoparticles with Aggregation‐Induced Emission Characteristics for Targeted In Vivo Imaging. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201200243

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.