The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Placental Drug Transport‐on‐a‐Chip: A Microengineered In Vitro Model of Transporter‐Mediated Drug Efflux in the Human Placental Barrier
Open accessAbstract
The current lack of knowledge about the effect of maternally administered drugs on the developing fetus is a major public health concern worldwide. The first critical step toward predicting the safety of medications in pregnancy is to screen drug compounds for their ability to cross the placenta. However, this type of preclinical study has been hampered by the limited capacity of existing in vitro and ex vivo models to mimic physiological drug transport across the maternal–fetal interface in the human placenta. Here the proof‐of‐principle for utilizing a microengineered model of the human placental barrier to simulate and investigate drug transfer from the maternal to the fetal circulation is demonstrated. Using the gestational diabetes drug glyburide as a model compound, it is shown that the microphysiological system is capable of reconstituting efflux transporter‐mediated active transport function of the human placental barrier to limit fetal exposure to maternally administered drugs. The data provide evidence that the placenta‐on‐a‐chip may serve as a new screening platform to enable more accurate prediction of drug transport in the human placenta.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increasing Prevalence of Gestational Diabetes Mellitus
Ferrara, A. (2007) · Diabetes Care · doi:10.2337/dc07-s206 · Cited by 1,171
A comparison of glyburide and insulin in women with gestational diabetes mellitus
Langer, O., Conway, D. L., Berkus, M. D., Xenakis, E. M.-J., & Gonzales, O. (2000) · New England Journal of Medicine · doi:10.1056/nejm200010193431601 · Cited by 924
DeSisto, C. L., Kim, S. Y., & Sharma, A. J. (2014) · Preventing Chronic Disease · doi:10.5888/pcd11.130415 · Cited by 577
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Enabling Technologies for Personalized and Precision Medicine
Ho, D., Quake, S. R., McCabe, E. R. B., Chng, W. J., Chow, E. K., Ding, X., Gelb, B. D., Ginsburg, G. S., Hassenstab, J., Ho, C.-M., et al. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.12.021 · Cited by 517
Advances in Hydrogels in Organoids and Organs‐on‐a‐Chip
Liu, H., Wang, Y., Cui, K., Guo, Y., Zhang, X., & Qin, J. (2019) · Advanced Materials · doi:10.1002/adma.201902042 · Cited by 353
Chatuphonprasert, W., Jarukamjorn, K., & Ellinger, I. (2018) · Frontiers in Pharmacology · doi:10.3389/fphar.2018.01027 · Cited by 269
Metadata
- Authors
- Blundell, C., Yi, Y., Ma, L., Tess, E. R., Farrell, M. J., Georgescu, A., Aleksunes, L. M., & Huh, D.
- Venue
- Advanced Healthcare Materials
- Publisher
- Wiley
- Published
- 2017-11-09
- Volume
- 7
- Issue
- 2
- ISSN
- 2192-2640 (ISSN-L)
- 2192-2659
- OpenAlex
- W2767396038
- Cited by
- 178
- References
- 4
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Placental Drug Transport‐on‐a‐Chip: A Microengineered In Vitro Model of Transporter‐Mediated Drug Efflux in the Human Placental Barrier. https://app.cochat.ai/papers/10.1002/adhm.201700786
- The paper
- Blundell, C., Yi, Y., Ma, L., Tess, E. R., Farrell, M. J., Georgescu, A., Aleksunes, L. M., & Huh, D. (2018). Placental Drug Transport‐on‐a‐Chip: A Microengineered In Vitro Model of Transporter‐Mediated Drug Efflux in the Human Placental Barrier. Advanced Healthcare Materials. https://doi.org/10.1002/adhm.201700786
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.