The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Nanoelectronic Carbon Dioxide Sensors
Abstract
Carbon nanotube field-effect transistors (NTFETs) coated with poly(ethyleneimine) (PEI) and starch polymers exhibit electrical conductance changes upon exposure to CO2 gas in air at ambient temperature (see Figure). This observation has furnished nanoelectronic CO2 sensors. Their small size and low power consumption has enormous potential in wireless sensing for industrial and medical CO2 sensor units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotube Molecular Wires as Chemical Sensors
Kong, J., Franklin, N. R., Zhou, C., Chapline, M. G., Peng, S., Cho, K., & Dai, H. (2000) · Science · doi:10.1126/science.287.5453.622 · Cited by 6,043
Room-temperature transistor based on a single carbon nanotube
Tans, S. J., Verschueren, A. R. M., & Dekker, C. (1998) · Nature · doi:10.1038/29954 · Cited by 5,425
Tasis, D., Tagmatarchis, N., Bianco, A., & Prato, M. (2006) · Chemical Reviews · doi:10.1021/cr050569o · Cited by 4,273
Ballistic carbon nanotube field-effect transistors
Javey, A., Guo, J., Wang, Q., Lundstrom, M., & Dai, H. (2003) · Nature · doi:10.1038/nature01797 · Cited by 3,187
Extreme Oxygen Sensitivity of Electronic Properties of Carbon Nanotubes
Collins, P. G., Bradley, K., Ishigami, M., & Zettl, A. (2000) · Science · doi:10.1126/science.287.5459.1801 · Cited by 2,974
Single- and multi-wall carbon nanotube field-effect transistors
Martel, R., Schmidt, T., Shea, H. R., Hertel, T., & Avouris, P. (1998) · Applied Physics Letters · doi:10.1063/1.122477 · Cited by 2,812
Logic Circuits with Carbon Nanotube Transistors
Bachtold, A., Hadley, P., Nakanishi, T., & Dekker, C. (2001) · Science · doi:10.1126/science.1065824 · Cited by 2,616
Functionalization of Single-Walled Carbon Nanotubes
Hirsch, A. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20020603)41:11<1853::aid-anie1853>3.0.co;2-n · Cited by 2,146
Reversible water-solubilization of single-walled carbon nanotubes by polymer wrapping
O'Connell, M. J., Boul, P., Ericson, L. M., Huffman, C., Wang, Y., Haroz, E., Kuper, C., Tour, J., Ausman, K. D., & Smalley, R. E. (2001) · Chemical Physics Letters · doi:10.1016/s0009-2614(01)00490-0 · Cited by 1,710
Functionalized Carbon Nanotubes: Properties and Applications
Sun, Y.-P., Fu, K., Lin, Y., & Huang, W. (2002) · Accounts of Chemical Research · doi:10.1021/ar010160v · Cited by 1,626
Cited by
Carbon Nanotube Chemical Sensors
Schroeder, V., Savagatrup, S., He, M., Lin, S., & Swager, T. M. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00340 · Cited by 1,131
Developments in Nanostructured Cathode Materials for High‐Performance Lithium‐Ion Batteries
Wang, Y., & Cao, G. (2008) · Advanced Materials · doi:10.1002/adma.200702242 · Cited by 1,116
Cao, Q., & Rogers, J. A. (2009) · Advanced Materials · doi:10.1002/adma.200801995 · Cited by 1,098
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Self-citationCarbon Nanotube Field‐Effect‐Transistor‐Based Biosensors
Allen, B. L., Kichambare, P. D., & Star, A. (2007) · Advanced Materials · doi:10.1002/adma.200602043 · Cited by 782
Self-citationExperimental Review of Graphene
Cooper, D. R., D’Anjou, B., Ghattamaneni, N., Harack, B., Hilke, M., Horth, A., Majlis, N., Massicotte, M., Vandsburger, L., Whiteway, E., et al. (2012) · ISRN Condensed Matter Physics · doi:10.5402/2012/501686 · Cited by 693
A dielectric-modulated field-effect transistor for biosensing
Im, H., Huang, X.-J., Gu, B., & Choi, Y.-K. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.180 · Cited by 635
Organic–Inorganic Hybrid Nanocomposite-Based Gas Sensors for Environmental Monitoring
Kaushik, A., Kumar, R., Arya, S. K., Nair, M., Malhotra, B. D., & Bhansali, S. (2015) · Chemical Reviews · doi:10.1021/cr400659h · Cited by 534
Synthesis and Enhanced Intercalation Properties of Nanostructured Vanadium Oxides
Wang, Y., & Cao, G. (2006) · Chemistry of Materials · doi:10.1021/cm052765h · Cited by 453
MOF‐Based Chemiresistive Gas Sensors: Toward New Functionalities
Jo, Y., Jo, Y. K., Lee, J., Jang, H. W., Hwang, I., & Yoo, D. J. (2023) · Advanced Materials · doi:10.1002/adma.202206842 · Cited by 410
Fluorescent Chemosensor for Detection and Quantitation of Carbon Dioxide Gas
Liu, Y., Tang, Y., Barashkov, N. N., Irgibaeva, I. S., Lam, J. W. Y., Hu, R., Birimzhanova, D., Yu, Y., & Tang, B. Z. (2010) · Journal of the American Chemical Society · doi:10.1021/ja103947j · Cited by 396
Carbon Nanotube/Polythiophene Chemiresistive Sensors for Chemical Warfare Agents
Wang, F., Gu, H., & Swager, T. M. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710795k · Cited by 391
Sun, Y., & Wang, H. H. (2007) · Advanced Materials · doi:10.1002/adma.200602975 · Cited by 371
Nanosensors for trace explosive detection
Senesac, L., & Thundat, T. G. (2008) · Materials Today · doi:10.1016/s1369-7021(08)70017-8 · Cited by 368
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Conducting‐Polymer Nanomaterials for High‐Performance Sensor Applications: Issues and Challenges
Yoon, H., & Jang, J. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801141 · Cited by 340
Recent advances in wide bandgap semiconductor biological and gas sensors
Pearton, S. J., Ren, F., Wang, Y.-L., Chu, B. H., Chen, K. H., Chang, C. Y., Lim, W., Lin, J., & Norton, D. P. (2010) · Progress in Materials Science · doi:10.1016/j.pmatsci.2009.08.003 · Cited by 286
Materials and Transducers Toward Selective Wireless Gas Sensing
Potyrailo, R. A., Surman, C., Nagraj, N., & Burns, A. (2011) · Chemical Reviews · doi:10.1021/cr2000477 · Cited by 285
Carbon nanotubes based transistors as gas sensors: State of the art and critical review
Bondavalli, P., Legagneux, P., & Pribat, D. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.04.025 · Cited by 284
Carbon nanotubes and its gas-sensing applications: A review
Han, T., Nag, A., Chandra Mukhopadhyay, S., & Xu, Y. (2019) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2019.03.053 · Cited by 281
Self-citationNanowire Chemical/Biological Sensors: Status and a Roadmap for the Future
Fennell, J. F., Liu, S. F., Azzarelli, J. M., Weis, J. G., Rochat, S., Mirica, K. A., Ravnsbæk, J. B., & Swager, T. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201505308 · Cited by 274
Metadata
- Authors
- Star, A., Han, T. ‐., Joshi, V., Gabriel, J. ‐. P., & Grüner, G.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2004-10-29
- Volume
- 16
- Issue
- 22
- Pages
- 2049-2052
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2011657699
- Cited by
- 319
- References
- 43
- FWCI
- 13.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.