The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A Luminescent Molecular Thermometer for Long‐Term Absolute Temperature Measurements at the Nanoscale
Abstract
A unique Eu3+/Tb3+ luminescent self-referencing nanothermometer allowing absolute measurements in the 10–350 K temperature range and sub-micrometer spatial resolution is reported (see Figure). It has up to 4.9%·K−1 temperature sensitivity and high photostability for long-term use. The combination of molecular thermometry, superparamagnetism and luminescence in a nanometric host matrix provides multifunctionality opening the way for new exciting applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of temperature measurement
Childs, P., Greenwood, J. R., & Long, C. A. (2000) · Review of Scientific Instruments · doi:10.1063/1.1305516 · Cited by 980
Lanthanide‐Containing Light‐Emitting Organic–Inorganic Hybrids: A Bet on the Future
Carlos, L. D., Ferreira, R. A. S., Bermudez, V. D. Z., & Ribeiro, S. J. L. (2009) · Advanced Materials · doi:10.1002/adma.200801635 · Cited by 945
Self-citationJordan, A., Scholz, R., Maier-Hauff, K., Johannsen, M., Wust, P., Nadobny, J., Schirra, H., Schmidt, H., Deger, S., Loening, S., et al. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)01239-7 · Cited by 731
Carbon nanothermometer containing gallium
Gao, Y., & Bando, Y. (2002) · Nature · doi:10.1038/415599a · Cited by 560
Hydrophilic Fluorescent Nanogel Thermometer for Intracellular Thermometry
Gota, C., Okabe, K., Funatsu, T., Harada, Y., & Uchiyama, S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja807714j · Cited by 524
Peng, H., Stich, M. I. J., Yu, J., Sun, L., Fischer, L. H., & Wolfbeis, O. S. (2010) · Advanced Materials · doi:10.1002/adma.200901614 · Cited by 457
Quantum-dot optical temperature probes
Walker, G. W., Sundar, V. C., Rudzinski, C. M., Wun, A. W., Bawendi, M. G., & Nocera, D. G. (2003) · Applied Physics Letters · doi:10.1063/1.1620686 · Cited by 415
Thermometer design at the nanoscale
Lee, J., & Kotov, N. A. (2007) · Nano Today · doi:10.1016/s1748-0132(07)70019-1 · Cited by 201
Aigouy, L., Saïdi, E., Lalouat, L., Labéguerie-Egéa, J., Mortier, M., Löw, P., & Bergaud, C. (2009) · Journal of Applied Physics · doi:10.1063/1.3233940 · Cited by 46
Cited by
Luminescent probes and sensors for temperature
Wang, X.-D., Wolfbeis, O. S., & Meier, R. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60102a · Cited by 1,647
Brites, C. D. S., Lima, P. P., Silva, N. J. O., Millán, A., Amaral, V. S., Palacio, F., & Carlos, L. D. (2012) · Nanoscale · doi:10.1039/c2nr30663h · Cited by 1,592
Self-citationEmerging Multifunctional Metal–Organic Framework Materials
Li, B., Wen, H., Cui, Y., Zhou, W., Qian, G., & Chen, B. (2016) · Advanced Materials · doi:10.1002/adma.201601133 · Cited by 1,587
Jaque, D., & Vetrone, F. (2012) · Nanoscale · doi:10.1039/c2nr30764b · Cited by 1,507
Okabe, K., Inada, N., Gota, C., Harada, Y., Funatsu, T., & Uchiyama, S. (2012) · Nature Communications · doi:10.1038/ncomms1714 · Cited by 1,203
Metadata
- Authors
- Brites, C. D. S., Lima, P. P., Silva, N. J. O., Millán, A., Amaral, V. S., Palacio, F., & Carlos, L. D.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2010-08-30
- Volume
- 22
- Issue
- 40
- Pages
- 4499-4504
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2029825894
- Cited by
- 475
- References
- 9
- FWCI
- 8.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.