The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Polycrystalline Graphene Ribbons as Chemiresistors
Abstract
Polycrystalline graphene sensors easily obtained through chemical vapor deposition (CVD) have been developed for chemical sensing. We show that linear defects or continuous lines of point defects on these sensors result in significantly higher sensitivity than that of pristine graphene and carbon nanotube film sensors. Further sensitivity enhancement is obtained by cutting the graphene into ribbons of width comparable to the linear defect dimensions (micrometers).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Yuan, W., & Shi, G. (2013) · Journal of Materials Chemistry A · doi:10.1039/c3ta11774j · Cited by 1,073
Yang, S., Jiang, C., & Wei, S.-H. (2017) · Applied Physics Reviews · doi:10.1063/1.4983310 · Cited by 876
Two‐Dimensional Nanostructured Materials for Gas Sensing
Liu, X., Ma, T., Pinna, N., & Zhang, J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201702168 · Cited by 851
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Chemical sensing with 2D materials
Anichini, C., Czepa, W., Pakulski, D., Aliprandi, A., Ciesielski, A., & Samorì, P. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00417j · Cited by 756
Graphene–metal oxide nanohybrids for toxic gas sensor: A review
Gupta Chatterjee, S., Chatterjee, S., Ray, A. K., & Chakraborty, A. K. (2015) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.070 · Cited by 737
Di Bartolomeo, A. (2016) · Physics Reports · doi:10.1016/j.physrep.2015.10.003 · Cited by 605
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
High‐Performance NO2 Sensors Based on Chemically Modified Graphene
Yuan, W., Liu, A., Huang, L., Li, C., & Shi, G. (2013) · Advanced Materials · doi:10.1002/adma.201203172 · Cited by 453
Jeong, S., Kim, J., & Lee, J. (2020) · Advanced Materials · doi:10.1002/adma.202002075 · Cited by 415
Metal-oxide semiconductors for carbon monoxide (CO) gas sensing: A review
Mahajan, S., & Jagtap, S. (2020) · Applied Materials Today · doi:10.1016/j.apmt.2019.100483 · Cited by 400
Liu, S., Yu, B., Zhang, H., Fei, T., & Zhang, T. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.086 · Cited by 364
Yang, Z., Jiang, L., Wang, J., Liu, F., He, J., Liu, A., Lv, S., You, R., Yan, X., Sun, P., et al. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128828 · Cited by 357
Ultrafast and sensitive room temperature NH3 gas sensors based on chemically reduced graphene oxide
Hu, N., Yang, Z., Wang, Y., Zhang, L., Wang, Y., Huang, X., Wei, H., Wei, L., & Zhang, Y. (2014) · Nanotechnology · doi:10.1088/0957-4484/25/2/025502 · Cited by 281
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Metadata
- Authors
- Salehi‐Khojin, A., Estrada, D., Lin, K. Y., Bae, M., Xiong, F., Pop, E., & Masel, R. I.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2011-11-23
- Volume
- 24
- Issue
- 1
- Pages
- 53-57
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W1973341977
- Cited by
- 203
- References
- 1
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.