Cited by 300Perovskite Materials and ApplicationsNanowire Synthesis and ApplicationsCCD and CMOS Imaging Sensors

3D Arrays of 1024‐Pixel Image Sensors based on Lead Halide Perovskite Nanowires

Gu, Leilei, Tavakoli, Mohammad Mahdi, Zhang, Daquan, Zhang, Qianpeng, Waleed, Aashir, Xiao, Yiqun, Tsui, Kwong‐Hoi, Lin, Yuanjing +3 more·2016·Advanced Materials

Abstract

Large-scale and highly ordered 3D perov-skite nanowire (NW) arrays are achieved in nanoengineering templates by a unique vapor-solid-solid reaction process. The excellent material properties, in conjunction with the high integration density of the NW arrays, make them promising for 3D integrated nanoelectronics/optoelectronics. Image sensors with 1024 pixels are assembled and characterized to demonstrate the technological potency.

Integrity signals

Registry

Crossref · 10.1002/adma.201601603

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • These perovskite nanowire arrays hold great potential for optoelectronic applications like photodetectors and LEDs.

    “These perovskite nanowires arrays hold great potential for optoelectronic applications like photodetectors and LEDs (Figure 11C).”
  • Large-scale, high-density arrays of lead halide perovskite nanowires with precise geometry are fabricated, enabling the electrical addressing of individual perovskite nanowires for very large-scale integration in electronics and optoelectronics.

    “Furthermore, large-scale, high-density arrays of lead halide perovskite nanowires with precise geometry are fabricated, enabling the electrical addressing of individual perovskite nanowires for very large-scale integration in electronics and optoelectronics [180].”
  • Image sensors with 1024 pixels have been demonstrated, showcasing their ability to capture still images and video.

    “Image sensors with 1024 pixels have been demonstrated, showcasing their ability to capture still images and video.”

The citation lists haven’t been fetched yet

References 38 · Cited by 300

Authors
Gu, L., Tavakoli, M. M., Zhang, D., Zhang, Q., Waleed, A., Xiao, Y., Tsui, K., Lin, Y., Liao, L., Wang, J., & Fan, Z.
Affiliations
  • Hong Kong University of Science and Technology (HK)
  • Wuhan University (CN)
Corresponding author
Fan, Zhiyong
Venue
Advanced Materials
Publisher
Wiley
Published
2016-09-20
Volume
28
Issue
44
Pages
9713-9721
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2522787152
Cited by
300
References
38
Citations by year
2026: 18 · 2025: 20 · 2024: 38 · 2023: 30 · 2022: 43 · 2021: 38 · 2020: 36 · 2019: 28 · 2018: 27 · 2017: 21 · 2016: 1
FWCI
11.84
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • Rare & Special e-Zone (The Hong Kong University of Science and Technology) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Perovskite Materials and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Nanowire Synthesis and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › CCD and CMOS Imaging Sensors
Keywords
image sensors, optoelectronics, 3D integration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review