The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Encoding, Reading, and Transforming Information Using Multifluorescent Supramolecular Polymeric Hydrogels
Abstract
Traditional (1D, 2D, and 3D) codes are widely used to provide convenient readouts of encoded information. However, manipulating and transforming the encoded information is typically difficult to achieve. Here, the preparation of three fluorescent (blue, green, and red) hydrogels containing both tetracationic receptor–anion recognition motifs and gel‐specific fluorophores is reported, which may be used as building blocks to construct through physical adhesion fluorescent color 3D codes (Code A, Code B, and Code C) that may be read out by a smartphone. As a result, parts of the individual gel components that make up Code B can be replaced with other gel building blocks to form Code A via a cut and adhesion approach. A fluorophore responsive to ammonia is further incorporated into one of the hydrogels. This allows the gel block‐derived pattern that makes up Code C to be converted to Code A by chemical means. Therefore, the encoded information produced by patterns of the present hydrogels may be transformed through either physical action or by exposure to a chemical stimulus. Due to the nature of the soft materials involved, the codes can be used as wearable materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Big data consumer analytics and the transformation of marketing
Erevelles, S., Fukawa, N., & Swayne, L. (2016) · Journal of Business Research · doi:10.1016/j.jbusres.2015.07.001 · Cited by 1,377
Cited by
Xia, D., Wang, P., Ji, X., Khashab, N. M., Sessler, J. L., & Huang, F. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00839 · Cited by 734
Self-citationJi, X., Ahmed, M., Long, L., Khashab, N. M., Huang, F., & Sessler, J. L. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00955d · Cited by 293
Self-citationMulticolor Fluorescent Polymeric Hydrogels
Wei, S., Li, Z., Lu, W., Liu, H., Zhang, J., Chen, T., & Tang, B. Z. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202007506 · Cited by 281
Metadata
- Authors
- Ji, X., Wu, R., Long, L., Ke, X., Guo, C., Ghang, Y., Lynch, V. M., Huang, F., & Sessler, J. L.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2018-01-22
- Volume
- 30
- Issue
- 11
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2793129180
- Cited by
- 237
- References
- 2
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Encoding, Reading, and Transforming Information Using Multifluorescent Supramolecular Polymeric Hydrogels. https://app.cochat.ai/papers/10.1002/adma.201705480
- The paper
- Ji, X., Wu, R., Long, L., Ke, X., Guo, C., Ghang, Y., Lynch, V. M., Huang, F., & Sessler, J. L. (2018). Encoding, Reading, and Transforming Information Using Multifluorescent Supramolecular Polymeric Hydrogels. Advanced Materials. https://doi.org/10.1002/adma.201705480
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.