The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Highly Stretchable and Real‐Time Healable Supercapacitor
Abstract
In addition to a high specific capacitance, a large stretchability and self‐healing properties are also essential to improve the practicality and reliability of supercapacitors in portable and wearable electronics. However, the integration of multiple functions into one device remains challenging. Here, the construction of a highly stretchable and real‐time omni‐healable supercapacitor is demonstrated by sandwiching the polypyrrole‐incorporated gold nanoparticle/carbon nanotube (CNT)/poly(acrylamide) (GCP@PPy) hydrogel electrodes with a CNT‐free GCP (GP) hydrogel as the electrolyte and chemically soldering an Ag nanowire film to the hydrogel electrode as the current collector. The newly developed dynamic metal‐thiolate (M‐SR, M = Au, Ag) bond‐induced integrated configuration, with an intrinsically powerful electrode and electrolyte, enables the assembled supercapacitor to deliver an areal capacitance of 885 mF cm−2 and an energy density of 123 µWh cm−2, which are among the highest‐reported values for stretchable supercapacitors. Notably, the device exhibits a superhigh stretching strain of 800%, rapid optical healing capability, and significant real‐time healability during the charge–discharge process. The exceptional performance combined with the facile assembly method confirms this multifunctional device as the best performer among all the flexible supercapacitors reported to date.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Cited by
Zhao, Z., Xia, K., Hou, Y., Zhang, Q., Ye, Z., & Lu, J. (2021) · Chemical Society Reviews · doi:10.1039/d1cs00800e · Cited by 490
Li, X., He, L., Li, Y., Chao, M., Li, M., Wan, P., & Zhang, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c01751 · Cited by 473
Cheng, T., Zhang, Y., Wang, S., Chen, Y., Gao, S., Wang, F., Lai, W., & Huang, W. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202101303 · Cited by 308
Conductive polymer based hydrogels and their application in wearable sensors: a review
Liu, D., Huyan, C., Wang, Z., Guo, Z., Zhang, X., Torun, H., Mulvihill, D., Xu, B. B., & Chen, F. (2023) · Materials Horizons · doi:10.1039/d3mh00056g · Cited by 282
Lan, B., Xiang, Y., Luo, X., Wu, D., Zhang, L., Duan, J., Guo, M., Ito, Y., & Liu, Y. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.132886 · Cited by 53
Metadata
- Authors
- Chen, C., Qin, H., Cong, H., & Yu, S.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-03-28
- Volume
- 31
- Issue
- 19
- Pages
- e1900573-e1900573
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2934241304
- Cited by
- 321
- References
- 1
- FWCI
- 13.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Highly Stretchable and Real‐Time Healable Supercapacitor. https://app.cochat.ai/papers/10.1002/adma.201900573
- The paper
- Chen, C., Qin, H., Cong, H., & Yu, S. (2019). A Highly Stretchable and Real‐Time Healable Supercapacitor. Advanced Materials. https://doi.org/10.1002/adma.201900573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.