The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers
Abstract
Skin interstitial fluid (ISF) is considered as an emerging source of biomarkers with physiological and medical significance. Microneedle arrays (MNs) provide a promising means for painless, noninvasive detection of these biomarkers. Here, novel MNs integrated with photonic crystal (PhC) barcodes are presented, and multiplex specific detection of ISF biomarkers is realized for the first time. The PhC barcodes‐loaded flexible MNs are simply fabricated by replicating dynamic ferrofluid‐cast micromoldings. When the prepared MNs are inserted into skin, they can enrich specific biomarkers to their probes‐decorated PhC barcodes. Thus, by adding corresponding fluorescent probes to form sandwich immunocomplexes, the relative content of the biomarkers can be read out through the fluorescence intensity of the barcodes; meanwhile, the species of these biomarkers can be clearly distinguished by the reflection peaks of the PhC barcodes. Based on the encoded MNs, their sensitivity, flexibility, and versatility of capturing and detecting three inflammatory cytokines are demonstrated in a sepsis mice model. Compared with existing MNs for ISF detection, the encoded MNs not only possess equivalent detection effects with less post‐processing and simplified procedures, but can also detect multiple biomarkers simultaneously, which makes them ideal in many clinical and biomedical detection areas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Functional and Biomimetic Materials for Engineering of the Three-Dimensional Cell Microenvironment
Huang, G., Li, F., Zhao, X., Ma, Y., Li, Y., Lin, M., Jin, G., Lu, T. J., Genin, G. M., & Xu, F. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00094 · Cited by 825
Cited by
Zhang, X., Chen, G., Liu, Y., Sun, L., Sun, L., & Zhao, Y. (2020) · ACS Nano · doi:10.1021/acsnano.0c01059 · Cited by 363
Self-citationLab under the Skin: Microneedle Based Wearable Devices
Teymourian, H., Tehrani, F., Mahato, K., & Wang, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002255 · Cited by 310
Non-invasive monitoring of interstitial fluid lactate through an epidermal iontophoretic device
De la Paz, E., Saha, T., Del Caño, R., Seker, S., Kshirsagar, N., & Wang, J. (2023) · Talanta · doi:10.1016/j.talanta.2022.124122 · Cited by 63
Recent progress of micro/nanomotors to overcome physiological barriers in the gastrointestinal tract
Zhang, S., Zhu, C., Huang, W., Liu, H., Yang, M., Zeng, X., Zhang, Z., Liu, J., Shi, J., Hu, Y., et al. (2023) · Journal of Controlled Release · doi:10.1016/j.jconrel.2023.07.005 · Cited by 59
Metadata
- Authors
- Zhang, X., Chen, G., Bian, F., Cai, L., & Zhao, Y.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2019-07-04
- Volume
- 31
- Issue
- 37
- Pages
- e1902825-e1902825
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W2954840343
- Cited by
- 252
- References
- 2
- FWCI
- 10.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers. https://app.cochat.ai/papers/10.1002/adma.201902825
- The paper
- Zhang, X., Chen, G., Bian, F., Cai, L., & Zhao, Y. (2019). Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers. Advanced Materials. https://doi.org/10.1002/adma.201902825
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.