Cited by 148Luminescence and Fluorescent MaterialsOptical Imaging and Spectroscopy TechniquesMolecular Sensors and Ion Detection

NIR‐II‐Excited Intravital Two‐Photon Microscopy Distinguishes Deep Cerebral and Tumor Vasculatures with an Ultrabright NIR‐I AIE Luminogen

Wang, Shaowei, Liu, Jie, Goh, Chi Ching, Ng, Lai Guan, Liu, Bin·2019·Advanced Materials

Abstract

Intravital fluorescence imaging of vasculature morphology and dynamics in the brain and in tumors with large penetration depth and high signal‐to‐background ratio (SBR) is highly desirable for the study and theranostics of vascular‐related diseases and cancers. Herein, a highly bright fluorophore (BTPETQ) with long‐wavelength absorption and aggregation‐induced near‐infrared (NIR) emission (maximum at ≈700 nm) is designed for intravital two‐photon fluorescence (2PF) imaging of a mouse brain and tumor vasculatures under NIR‐II light (1200 nm) excitation. BTPETQ dots fabricated via nanoprecipitation show uniform size of around 42 nm and a high quantum yield of 19 ± 1% in aqueous media. The 2PF imaging of the mouse brain vasculatures labeled by BTPETQ dots reveals a 3D blood vessel network with an ultradeep depth of 924 µm. In addition, BTPETQ dots show enhanced 2PF in tumor vasculatures due to their unique leaky structures, which facilitates the differentiation of normal blood vessels from tumor vessels with high SBR in deep tumor tissues. Moreover, the extravasation and accumulation of BTPETQ dots in deep tumor (more than 900 µm) is visualized under NIR‐II excitation. This study highlights the importance of developing NIR‐II light excitable efficient NIR fluorophores for in vivo deep tissue and high contrast tumor imaging.

Integrity signals

Registry

Crossref · 10.1002/adma.201904447

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

The citation lists haven’t been fetched yet

References 58 · Cited by 148

Authors
Wang, S., Liu, J., Goh, C. C., Ng, L. G., & Liu, B.
Affiliations
  • National University of Singapore (SG)
  • Nanjing Tech University (CN)
  • Agency for Science, Technology and Research (SG)
Corresponding author
  • Liu, Jie
  • Liu, Bin
Venue
Advanced Materials
Publisher
Wiley
Published
2019-09-15
Volume
31
Issue
44
Pages
e1904447-e1904447
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W2974272548
Cited by
148
References
58
Citations by year
2026: 10 · 2025: 17 · 2024: 19 · 2023: 19 · 2022: 24 · 2021: 33 · 2020: 24 · 2019: 2
FWCI
7.49
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials (publishedVersion)
  • PubMed (publishedVersion)
  • National University of Singapore (submittedVersion)
Funders
  • National Research Foundation Singapore (R279‐000‐483‐281, R279‐000‐444‐281)
  • National University of Singapore (R279‐000‐482‐133)
  • National Natural Science Foundation of China (21402219)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
Keywords
aggregation-induced emission, two-photon fluorescence imaging, intravital imaging, cerebral vasculature, tumor vasculature, deep tissue imaging, nanoprecipitation, extravasation, tumor imaging, blood vessel networks
MeSH terms
Animals, Blood Vessels, Brain, Cell Survival, Fluorescent Dyes, HeLa Cells, Humans, Mice, Inbred BALB C, Neoplasms, Pyrroles, Thiadiazoles, Tissue Distribution, Spectroscopy, Near-Infrared, Microscopy, Fluorescence, Multiphoton, Quantum Dots

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review