The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Schottky‐Contacted Nanowire Sensors
Abstract
The progress of the Internet‐of‐Things in the past few years has necessitated the support of high‐performance sensors. Schottky‐contacted nanowire sensors have attracted considerable attention owing to their high sensitivity and fast response time. Their progress is reviewed here, based on several kinds of important nanowires, for applications such as bio/chemical sensors, gas sensors, photodetectors, and strain sensors. Although Schottky‐contacted nanowire sensors deliver excellent performance in these fields, they can be further improved by various methods, including defect engineering, surface modification, the piezotronic effect, and the piezophototronic effect, all of which are discussed here. With regard to practical applications, further efforts are required to address challenges such as the stability, selectivity, ultrafast response, multifunctionality, flexibility, distributed energy supply, and sustainability of Schottky‐contacted nanowire sensors. Finally, future perspectives and solutions are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
Transcatheter Self‐Powered Ultrasensitive Endocardial Pressure Sensor
Liu, Z., Ma, Y., Ouyang, H., Shi, B., Li, N., Jiang, D., Xie, F., Qu, D., Zou, Y., Huang, Y., et al. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807560 · Cited by 308
Self-citationHybrid Metamaterial Absorber Platform for Sensing of CO 2 Gas at Mid‐IR
Hasan, D., & Lee, C. (2018) · Advanced Science · doi:10.1002/advs.201700581 · Cited by 173
All-Dielectric Surface-Enhanced Infrared Absorption-Based Gas Sensor Using Guided Resonance
Chang, Y., Hasan, D., Dong, B., Wei, J., Ma, Y., Zhou, G., Ang, K. W., & Lee, C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b16623 · Cited by 115
Highly sensitive and flexible strain sensors based on vertical zinc oxide nanowire arrays
Zhang, W., Zhu, R., Nguyen, V., & Yang, R. (2014) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2013.11.004 · Cited by 111
Cited by
Naturally sourced hydrogels: emerging fundamental materials for next-generation healthcare sensing
Wang, Z., Wei, H., Huang, Y., Wei, Y., & Chen, J. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00813k · Cited by 392
Metadata
- Authors
- Meng, J., & Li, Z.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2020-06-02
- Volume
- 32
- Issue
- 28
- Pages
- e2000130-e2000130
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3031117315
- Cited by
- 183
- References
- 6
- FWCI
- 8.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Schottky‐Contacted Nanowire Sensors. https://app.cochat.ai/papers/10.1002/adma.202000130
- The paper
- Meng, J., & Li, Z. (2020). Schottky‐Contacted Nanowire Sensors. Advanced Materials. https://doi.org/10.1002/adma.202000130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.