CoChat

Ultrasensitive and Robust 120 keV Hard X‐Ray Imaging Detector based on Mixed‐Halide Perovskite CsPbBr3−nIn Single Crystals

Zhang, Peng, Hua, Yunqiu, Xu, Yadong, Sun, Qihao, Li, Xiang, Cui, Fucai, Liu, Lin, Bi, Yanxiao, Zhang, Guodong, Tao, Xutang · 2022 · Advanced Materials
Cited by 193

The DOI matches its Crossref record.

Abstract

The relatively low resistivity and severe ion migration in CsPbBr 3 significantly degrade the performance of X‐ray detectors due to their high detection limit and current drift. The electrical properties and X‐ray detection performances of CsPbBr 3−nIn single crystals are investigated by doping the iodine atoms into the melt‐grown CsPbBr 3. The resistivity of CsPbBr 3−nIn single crystals increases from 3.6 × 10 9 (CsPbBr 3) to 2.2 × 10 11 (CsPbBr 2 I) Ω cm, restraining the leak current and decreasing the detection limit of the detector. Additionally, CsPbBr 3−nIn single crystals exhibit stable dark currents, arising from their high ion migration activation energy. A record sensitivity of 6.3 × 104 µC Gy−1 cm−2 (CsPbBr 2.9 I 0.1) and a low detection limit of 54 nGy s−1 (CsPbBr 2 I) are achieved by CsPbBr 3−nIn single crystals for the 120 keV hard X‐ray detection under a 5000 V cm−1 electrical field. The CsPbBr 2.9 I 0.1 detector shows a stable current response with a dark current density of 0.58 µA cm−2 for 30 days and clear imaging for 120 keV Xrays at ambient conditions. The effective iodine atom doping strategy makes the CsPbBr 3−nIn single crystals promising for reproducible high‐energy hard X‐ray imaging systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202106562

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zhang, P., Hua, Y., Xu, Y., Sun, Q., Li, X., Cui, F., Liu, L., Bi, Y., Zhang, G., & Tao, X.
Venue
Advanced Materials
Publisher
Wiley
Published
2022-02-11
Volume
34
Issue
12
Pages
e2106562-e2106562
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W4207027198
Cited by
193
References
0
FWCI
26.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.