The DOI matches its Crossref record.
Stretchable, Breathable, and Stable Lead‐Free Perovskite/Polymer Nanofiber Composite for Hybrid Triboelectric and Piezoelectric Energy Harvesting
Open accessAbstract
Halide‐perovskite‐based mechanical energy harvesters display excellent electrical output due to their unique ferroelectricity and dielectricity. However, their high toxicity and moisture sensitivity impede their practical applications. Herein, a stretchable, breathable, and stable nanofiber composite (LPPS‐NFC) is fabricated through electrospinning of lead‐free perovskite/poly(vinylidene fluoride‐co‐hexafluoropropylene) (PVDF‐HFP) and styrene–ethylene–butylene–styrene (SEBS). The Cs 3 Bi 2 Br 9 perovskites serve as efficient electron acceptors and local nucleating agents for the crystallization of polymer chains, thereby enhancing the electron‐trapping capacity and polar crystalline phase in LPPS‐NFC. The excellent energy level matching between Cs 3 Bi 2 Br 9 and PVDF‐HFP boosts the electron transfer efficiency and reduces the charge loss, thereby promoting the electron‐trapping process. Consequently, this LPPS‐NFC‐based energy harvester displays an excellent electrical output (400 V, 1.63 µA cm−2, and 2.34 W m−2), setting a record of the output voltage among halide‐perovskite‐based nanogenerators. The LPPS‐NFC also exhibits excellent stretchability, waterproofness, and breathability, enabling the fabrication of robust wearable devices that convert mechanical energy from different biomechanical motions into electrical power to drive common electronic devices. The LPPS‐NFC‐based energy harvesters also endure extreme mechanical deformations (washing, folding, and crumpling) without performance degradation, and maintain stable electrical output up to 5 months, demonstrating their promising potential for use as smart textiles and wearable power sources.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Self-citationBiodegradable Piezoelectric Polymers: Recent Advancements in Materials and Applications
Ali, M., Bathaei, M. J., Istif, E., Karimi, S. N. H., & Beker, L. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202300318 · Cited by 211
Metadata
- Authors
- Jiang, F., Zhou, X., Lv, J., Chen, J., Chen, J., Kongcharoen, H., Zhang, Y., & Lee, P. S.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2022-03-20
- Volume
- 34
- Issue
- 17
- Pages
- e2200042-e2200042
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4214890820
- Cited by
- 265
- References
- 0
- FWCI
- 15.45
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable, Breathable, and Stable Lead‐Free Perovskite/Polymer Nanofiber Composite for Hybrid Triboelectric and Piezoelectric Energy Harvesting. https://app.cochat.ai/papers/10.1002/adma.202200042
- The paper
- Jiang, F., Zhou, X., Lv, J., Chen, J., Chen, J., Kongcharoen, H., Zhang, Y., & Lee, P. S. (2022). Stretchable, Breathable, and Stable Lead‐Free Perovskite/Polymer Nanofiber Composite for Hybrid Triboelectric and Piezoelectric Energy Harvesting. Advanced Materials. https://doi.org/10.1002/adma.202200042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.