CoChat

Revealing Trapped Carrier Dynamics at Buried Interfaces in Perovskite Solar Cells via Infrared‐Modulated Action Spectroscopy with Surface Photovoltage Detection

Open access

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Abstract

Interfacial engineering is a proven strategy to enhance the efficiency of perovskite solar cells (PeSCs) by controlling surface electronic defects and carrier trapping. The trap states at the “top” interface between the perovskite and upper charge extraction layers are experimentally accessible and have been extensively studied. However, the understanding of the unexposed “bottom” surface of the perovskite layer remains elusive, due to the lack of selective and non‐destructive tools to access buried interface. Here, a new spectroscopy technique is introduced that monitors nanosecond to millisecond dynamics of trapped carriers at the buried interfaces by combining optical trap activation by infrared light with surface photovoltage detection. Applied to various PeSC architectures, this method reveals that most interfacial traps reside between the perovskite and hole transport layer, suggesting a predominance of hole traps (e.g., cation and lead vacancies) over electron traps (e.g., halide vacancies) in the studied PeSC systems. The proposed new approach separates interfacial carrier‐loss contributions from the top and buried surfaces, providing design insights for achieving high‐performance PeSCs through interface optimization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/adma.202502160

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 J–V curves of PeSCs with a) conventional and b) inverted structures. Insets in (a) and (b) show the corresponding device architectures. c) Schematic illustration of SPV measurement. Chromium is evaporated onto the surface of the SPV probe to establish the electrical connection. The light is incident from the glass side of the sample. Light‐modulated SPV spectra of half‐cell stacks with/without the top CTL in (d) conventional and (e) inverted architectures. Silicon Carbide lamp is used for providing light source, while monochromator is employed for wavelength selection.
Figure 1 J–V curves of PeSCs with a) conventional and b) inverted structures. Insets in (a) and (b) show the corresponding device architectures. c) Schematic illustration of SPV measurement. Chromium is evaporated onto the surface of the SPV probe to establish the electrical connection. The light is incident from the glass side of the sample. Light‐modulated SPV spectra of half‐cell stacks with/without the top CTL in (d) conventional and (e) inverted architectures. Silicon Carbide lamp is used for providing light source, while monochromator is employed for wavelength selection.CC BY · PubMed Central
Figure 2 a) Conceptual diagram and working principle of the PP‐SPV setup. b) Illustration of pump‐push effect from a full n‐i‐p device observed by SPV detection. c) The concentration of trapped carriers as a function of pump intensity in a conventional PeSC (Pump: 450 nm; Push: 980 nm, 10 600 mW cm‒2). d) The concentration of trapped carriers as a function of pump intensity in an inverted PeSC (Pump: 450 nm; Push intensity: 20 800 mW cm‒2). e) Dynamics of charge trapping in a conventional device traced by PP‐PC and PP‐SPV (Pump: 515 nm; Push: 1064 nm, 1.34 mJ cm‒2). f) Dynamics of charge trapping in an inverted device traced by PP‐PC and PP‐SPV (Pump: 515 nm; Push: 1064 nm, 1.91 mJ cm‒2). To improve the signal‐to‐noise ratio, the transient PP‐SPV results shown in (e) and (f) are the averaged curves derived from pump‐fluence‐independent dynamics shown in Figures S6 and S7 (Supporting Information). The solid fitting lines are utilized as guides for eyes.
Figure 2 a) Conceptual diagram and working principle of the PP‐SPV setup. b) Illustration of pump‐push effect from a full n‐i‐p device observed by SPV detection. c) The concentration of trapped carriers as a function of pump intensity in a conventional PeSC (Pump: 450 nm; Push: 980 nm, 10 600 mW cm‒2). d) The concentration of trapped carriers as a function of pump intensity in an inverted PeSC (Pump: 450 nm; Push intensity: 20 800 mW cm‒2). e) Dynamics of charge trapping in a conventional device traced by PP‐PC and PP‐SPV (Pump: 515 nm; Push: 1064 nm, 1.34 mJ cm‒2). f) Dynamics of charge trapping in an inverted device traced by PP‐PC and PP‐SPV (Pump: 515 nm; Push: 1064 nm, 1.91 mJ cm‒2). To improve the signal‐to‐noise ratio, the transient PP‐SPV results shown in (e) and (f) are the averaged curves derived from pump‐fluence‐independent dynamics shown in Figures S6 and S7 (Supporting Information). The solid fitting lines are utilized as guides for eyes.CC BY · PubMed Central
Figure 3 a) Perovskite half cells with different configurations. b) Linear growth of the IR‐induced SPV signals (ΔV) as increasing push intensity observed from samples with n‐i‐p structure. All data is fitted with linear equation (Pump intensity: 14 633 mW cm‒2). Normalized nTC as a function of pump intensity for whole/half devices with c) conventional configuration (Pump: 450 nm; Push: 980 nm, 10 600 mW cm‒2) and d) inverted configuration (Pump: 450 nm; Push: 980 nm, 20 800 mW cm‒2). The fitting lines in (c) and (d) are based on power law. Time‐resolved dynamics of the trapped carriers for (e) conventional half devices with and without the top Spiro layer (Pump: 515 nm; Push: 1064 nm, 1.91 mJ cm‒2), and f) inverted half devices with and without top C60 layer (Pump: 515 nm; Push: 1064 nm, 1.34 mJ cm‒2). To improve the signal‐to‐noise ratio, the transient PP‐SPV results in (e) and (f) are the averaged curves derived from pump‐fluence‐independent dynamics shown in Figures S16 and S19 (Supporting Information). The solid lines in (e) and (f) are used as guides for eyes. The trap filling time (τrise ), is defined as the time taken to reach 90% of the signal's full height. Concentration of trapped carriers at one/both interface(s) as the function of time in samples with different layers assembled as (g) conventional device configuration and (h) inverted device configuration, simulated by drift‐diffusion model. i) The schematic illustration of the correlation between interfacial trap distribution and interfacial trap filling dynamics in conventional/inverted cells.
Figure 3 a) Perovskite half cells with different configurations. b) Linear growth of the IR‐induced SPV signals (ΔV) as increasing push intensity observed from samples with n‐i‐p structure. All data is fitted with linear equation (Pump intensity: 14 633 mW cm‒2). Normalized nTC as a function of pump intensity for whole/half devices with c) conventional configuration (Pump: 450 nm; Push: 980 nm, 10 600 mW cm‒2) and d) inverted configuration (Pump: 450 nm; Push: 980 nm, 20 800 mW cm‒2). The fitting lines in (c) and (d) are based on power law. Time‐resolved dynamics of the trapped carriers for (e) conventional half devices with and without the top Spiro layer (Pump: 515 nm; Push: 1064 nm, 1.91 mJ cm‒2), and f) inverted half devices with and without top C60 layer (Pump: 515 nm; Push: 1064 nm, 1.34 mJ cm‒2). To improve the signal‐to‐noise ratio, the transient PP‐SPV results in (e) and (f) are the averaged curves derived from pump‐fluence‐independent dynamics shown in Figures S16 and S19 (Supporting Information). The solid lines in (e) and (f) are used as guides for eyes. The trap filling time (τrise ), is defined as the time taken to reach 90% of the signal's full height. Concentration of trapped carriers at one/both interface(s) as the function of time in samples with different layers assembled as (g) conventional device configuration and (h) inverted device configuration, simulated by drift‐diffusion model. i) The schematic illustration of the correlation between interfacial trap distribution and interfacial trap filling dynamics in conventional/inverted cells.CC BY · PubMed Central
Figure 4 a) The steady‐state PL spectrum and b) Transient PL kinetics of perovskite films with and without bottom interface passivation (Glass/PVP/PVSK and Glass/PVSK, receptively). c) J–V characteristics of p‐i‐n device with buried interface passivation (ITO/NiO x /SAM/PVP/PVSK/OAI/C60/BCP/Ag). d) Dynamics of trapped carriers at bottom interface before and after interfacial passivation (ITO/NiO x /SAM/PVSK/OAI and ITO/NiO x /SAM/PVP/PVSK/OAI, respectively) (Pump: 515 nm, 28.9 uJ cm‒2; Push: 1064 nm, 2.10 mJ cm‒2). The amplitude of ΔV/V for passivated sample is multiplied by 5.2 times for better comparison. The solid lines in Figure 4b,d is used as guides for eyes.
Figure 4 a) The steady‐state PL spectrum and b) Transient PL kinetics of perovskite films with and without bottom interface passivation (Glass/PVP/PVSK and Glass/PVSK, receptively). c) J–V characteristics of p‐i‐n device with buried interface passivation (ITO/NiO x /SAM/PVP/PVSK/OAI/C60/BCP/Ag). d) Dynamics of trapped carriers at bottom interface before and after interfacial passivation (ITO/NiO x /SAM/PVSK/OAI and ITO/NiO x /SAM/PVP/PVSK/OAI, respectively) (Pump: 515 nm, 28.9 uJ cm‒2; Push: 1064 nm, 2.10 mJ cm‒2). The amplitude of ΔV/V for passivated sample is multiplied by 5.2 times for better comparison. The solid lines in Figure 4b,d is used as guides for eyes.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 51 references

Research works printed but not linked: 2

  1. A. Wang, K. Bushick, N. Pant, W. Lee, X. Zhang, J. Leveillee, F. Giustino, S. Poncé, E. Kioupakis, Appl. Phys. Lett. 2024, 124, 172013.
  2. D. deQuilettes, S. Vorpahl, S. D. Stranks, H. Nagaoka, G. Eperon, M. E. Eperon, H. H. Snaith, D. S. Ginger, Science 2015, 348, 6235. 25931446

Cited by

See all 29

Metadata

Authors
Hu, B., Zhang, T., Li, L., Ning, H., Min, G., Wang, T., Chen, M., Pan, J., Xu, N., Macdonald, T. J., Gao, F., Levine, I., Chen, Z., & Bakulin, A. A.
Affiliations
  • Imperial College London (GB)
  • Linköping University (SE)
  • University College London (GB)
  • Hebrew University of Jerusalem (IL)
Corresponding author
  • Levine, Igal
  • Chen, Ziming
  • Bakulin, Artem A.
Venue
Advanced Materials
Publisher
Wiley
Published
2025-04-11
Volume
37
Issue
26
Pages
e2502160-e2502160
ISSN
  • 0935-9648 (ISSN-L)
  • 1521-4095
OpenAlex
W4409360788
Cited by
23
References
51
Citations by year
2026: 14 · 2025: 9
FWCI
5.13
Type
journal article
Language
en
Open access
Licence
Locations
  • Advanced Materials (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
  • UCL Discovery (University College London) (submittedVersion)
Funders
  • UK Research and Innovation (EP/X027465/1)
  • Engineering and Physical Sciences Research Council (EP/X030822/1)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Perovskite Materials and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Organic Electronics and Photovoltaics
  • Physical Sciences › Materials Science › Materials Chemistry › Ferroelectric and Piezoelectric Materials
Keywords
perovskite solar cells, buried interfaces, interfacial trap states, hole transport layer, cation vacancies, lead vacancies, halide vacancies, interface engineering, charge extraction layers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.