The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A High‐Performances Flexible Temperature Sensor Composed of Polyethyleneimine/Reduced Graphene Oxide Bilayer for Real‐Time Monitoring
Abstract
The temperature sensors are urgently required for real‐time temperature monitoring in healthcare, disease diagnosis, and other areas. In this work, a skin‐attachable flexible temperature sensor composed of polyethyleneimine/reduced graphene oxide bilayer is developed on polyimide substrate by a facile spray‐dipping process. The spectroscopy properties of sensing films are examined and analyzed in details and demonstrated the partial reduction of graphene oxide film. The prepared sensor exhibits high sensitivity (1.30% °C−1), linearity (R2 = 0.999), accuracy (0.1 °C), and durability (60 d) for temperature sensing between 25 and 45 °C, which can fully satisfy the requirements of real‐time and long‐term skin temperature monitoring. Additionally, the practical applications in monitoring human skin temperature, breathing rate, finer touch, blow, and water droplet are performed, revealing its great potential in e‐skin, disease diagnosis, healthcare, and other fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Kanao, K., Harada, S., Yamamoto, Y., Honda, W., Arie, T., Akita, S., & Takei, K. (2015) · RSC Advances · doi:10.1039/c5ra03110a · Cited by 148
Hong, S. Y., Oh, J. H., Park, H., Yun, J. Y., Jin, S. W., Sun, L., Zi, G., & Ha, J. S. (2017) · NPG Asia Materials · doi:10.1038/am.2017.194 · Cited by 117
Cited by
Lin, M., Zheng, Z., Yang, L., Luo, M., Fu, L., Lin, B., & Xu, C. (2022) · Advanced Materials · doi:10.1002/adma.202107309 · Cited by 614
Flexible temperature sensors: A review
Arman Kuzubasoglu, B., & Kursun Bahadir, S. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.112282 · Cited by 369
Recent advances in humidity sensors for human body related humidity detection
Duan, Z., Jiang, Y., & Tai, H. (2021) · Journal of Materials Chemistry C · doi:10.1039/d1tc04180k · Cited by 365
Self-citationWang, Y.-F., Sekine, T., Takeda, Y., Yokosawa, K., Matsui, H., Kumaki, D., Shiba, T., Nishikawa, T., & Tokito, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-59432-2 · Cited by 316
Yao, P., Bao, Q., Yao, Y., Xiao, M., Xu, Z., Yang, J., & Liu, W. (2023) · Advanced Materials · doi:10.1002/adma.202300114 · Cited by 308
Metadata
- Authors
- Liu, Q., Tai, H., Yuan, Z., Zhou, Y., Su, Y., & Jiang, Y.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2019-01-15
- Volume
- 4
- Issue
- 3
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W2909032082
- Cited by
- 164
- References
- 4
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.