The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Semi‐Liquid‐Metal‐(Ni‐EGaIn)‐Based Ultraconformable Electronic Tattoo
Abstract
Because of its seamless skin interface, electronic skin has attracted increasing attention in the field of biomedical sensors and medical devices. Most electronic skins are based on organic or inorganic electronic materials. However, the low flexibility of inorganic materials and the limited conductivity of organic materials restricts their widespread use. A new approach is reported to fabricate electronic tattoos from Ni‐EGaIn, which has high conductivity (1.61 × 10 6 S m−1) and human‐skin compliance. This time‐effective and low‐cost method is mainly based on the adhesion selectivity of semi‐liquid metal (Ni‐EGaIn) on skin and polymethacrylate glue. Light‐emitting diode arrays, temperature sensors, heaters, and surface electrodes are successfully printed onto skin, and their function in monitoring, diagnosis, and medical treatment is demonstrated. Moreover, a human–machine interface is fabricated using this technique to fully bridge the gap between a human and an electronic circuit. This novel strategy not only provides an ultraconformable interface for use in biomedicine but also represents a path towards personal customization of electronic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Shin, G., Gomez, A. M., Al-Hasani, R., Jeong, Y. R., Kim, J., Xie, Z., Banks, A., Lee, S. M., Han, S. Y., Yoo, C. J., et al. (2017) · Neuron · doi:10.1016/j.neuron.2016.12.031 · Cited by 396
Cited by
Guo, R., Sun, X., Yuan, B., Wang, H., & Liu, J. (2019) · Advanced Science · doi:10.1002/advs.201901478 · Cited by 260
Self-citationLiquid Metal‐Based Soft Electronics for Wearable Healthcare
Park, Y., Lee, G., Jang, J., Yun, S. M., Kim, E., & Park, J. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202002280 · Cited by 258
Imperceptible liquid metal based tattoo for Human-Machine interface on hairy skin
Lin, W., Ai, L., Wang, Y., Yang, X., Liao, J., Pan, Q., Hong, Y., Liu, S., Long, Z., Khoo, B. L., et al. (2024) · Chemical Engineering Journal · doi:10.1016/j.cej.2024.151595 · Cited by 40
Metadata
- Authors
- Guo, R., Sun, X., Yao, S., Duan, M., Wang, H., Liu, J., & Deng, Z.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2019-05-22
- Volume
- 4
- Issue
- 8
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W2945719996
- Cited by
- 167
- References
- 3
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Semi‐Liquid‐Metal‐(Ni‐EGaIn)‐Based Ultraconformable Electronic Tattoo. https://app.cochat.ai/papers/10.1002/admt.201900183
- The paper
- Guo, R., Sun, X., Yao, S., Duan, M., Wang, H., Liu, J., & Deng, Z. (2019). Semi‐Liquid‐Metal‐(Ni‐EGaIn)‐Based Ultraconformable Electronic Tattoo. Advanced Materials Technologies. https://doi.org/10.1002/admt.201900183
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.