Light‐Directed Writing of Chemically Tunable Narrow‐Band Holographic Sensors
Open accessAbstract
This tunable holographic sensor offers interrogation and a reporting transducer as well as an analyte-responsive hydrogel, rendering it label-free and reusable. A single 6 ns laser pulse is used to fabricate holographic sensors consisting of silver nanoparticles arranged periodically within a polymer film. The tunability of the sensor is demonstrated through pH sensing of artificial urine and validated through computational modeling.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A biodegradable electronic patch integrated with flexible heaters was developed to deliver drugs on demand and allowed administering antibiotics.
“A biodegradable electronic patch integrated with flexible heaters was developed to deliver drugs on demand.92 This thermally‐controllable patch allowed administering antibiotics.”
From Wearables in Medicine (2018) · cites this paper as [92]
In vitro studies showed the patch successfully released cefazolin in agar plates inoculated with Staphylococcus aureus and E. coli.
“In vitro studies showed that the patch successfully released cefazolin in agar plates inoculated with Staphylococcus aureus and E. coli.”
From Wearables in Medicine (2018) · cites this paper as [92]
Wound patches (1.5 cm in diameter) with heaters resulted in a zone of inhibition up to 1.0 cm over 24 h compared to control samples without a heater.
“Wound patches (1.5 cm in diameter) having heaters resulted in a zone of inhibition up to 1.0 cm over 24 h as compared to control samples without a heater.92”
From Wearables in Medicine (2018) · cites this paper as [92]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 48 · Cited by 123
- Authors
- Yetisen, A. K., Butt, H., da Cruz Vasconcellos, F., Montelongo, Y., Davidson, C. A. B., Blyth, J., Chan, L., Carmody, J. B., Vignolini, S., Steiner, U., Baumberg, J. J., Wilkinson, T. D., & Lowe, C. R.
- Affiliations
- University of Cambridge (GB)
- Department of Chemical Engineering and Biotechnology University of Cambridge Tennis Court Road Cambridge CB21QT UK
- Children's Hospital of The King's Daughters (US)
- Corresponding author
- Yetisen, Ali K.
- ORCID
- Venue
- Advanced Optical Materials
- Publisher
- Wiley
- Published
- 2014-01-02
- Volume
- 2
- Issue
- 3
- Pages
- 250-254
- ISSN
- 2195-1071 (ISSN-L)
- OpenAlex
- W2038417146
- Cited by
- 123
- References
- 48
- Citations by year
- 2026: 1 · 2025: 5 · 2024: 2 · 2023: 7 · 2022: 13 · 2021: 11 · 2020: 10 · 2019: 10 · 2018: 5 · 2017: 8 · 2016: 21 · 2015: 16 · 2014: 14
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Locations
- Advanced Optical Materials (publishedVersion)
- Cambridge University Engineering Department Publications Database (submittedVersion)
- University of Birmingham Research Portal (University of Birmingham) (submittedVersion)
- Apollo (University of Cambridge) (submittedVersion)
- Apollo
- Funders
- Fundação de Amparo à Pesquisa do Estado de São Paulo
- Engineering and Physical Sciences Research Council (EP/G060649/1)
- Topics
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- holographic sensors, silver nanoparticles, tunable sensors, label-free detection, pH sensing, artificial urine, hydrogels, polymer films, computational modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review