CoChat

Body‐Integrated, Enzyme‐Triggered Degradable, Silk‐Based Mechanical Sensors for Customized Health/Fitness Monitoring and In Situ Treatment

Open access

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

Mechanical signals such as pressure and strain reflect important psychological and physiological states of the human body. Body‐integrated sensors, including skin‐mounted and surgically implanted ones, allow personalized health monitoring for the general population as well as patients. However, the development of such measuring devices has been hindered by the strict requirements for human‐biocompatible materials and the need for high performance sensors; most existing devices or sensors do not meet all the desired specifications. Here, a set of flexible, stretchable, wearable, implantable, and degradable mechanical sensors is reported with excellent mechanical robustness and compliance, outstanding biocompatibility, remotely‐triggered degradation, and excellent sensing performance, using a conductive silk fibroin hydrogel (CSFH). They can detect multiple mechanical signals such as pressure, strain, and bending angles. Moreover, combined with a drug‐loaded silk‐based microneedle array, sensor‐equipped devices are shown to be effective for real‐time monitoring and in situ treatment of epilepsy in a rodent model. These sensors offer potential applications in custom health monitoring wearables, and in situ treatment of chronic clinical disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/advs.201903802

Cites

Statistics

Figures

Figure 1 Degradable mechanical sensors using conductive silk fibroin hydrogels (CSFHs). a) Schematic diagram of the basic structure and the material components of the carbon nanotube (CNT)‐doped silk fibroin hydrogel. b) Photographs of the CSFHs under different deformations: i) initial state, ii) tension, iii) compression, and iv) bending, respectively. c) Representative SEM images of CSFHs under noted deformations. Inset in (i) show the 3D crosslinked networks of CNTs. d) Schematic illustration of the sensing mechanism: showing that resistance changes in response to the variation of the contact areas between CNTs, as caused by external forces. e) With the CSFH‐based mechanical sensors, the bending or unbending of fingers can be detected by the brightness of the LED. f) Dissolution of the CSFH in papain solution with concentration of 0.25%.
Figure 1 Degradable mechanical sensors using conductive silk fibroin hydrogels (CSFHs). a) Schematic diagram of the basic structure and the material components of the carbon nanotube (CNT)‐doped silk fibroin hydrogel. b) Photographs of the CSFHs under different deformations: i) initial state, ii) tension, iii) compression, and iv) bending, respectively. c) Representative SEM images of CSFHs under noted deformations. Inset in (i) show the 3D crosslinked networks of CNTs. d) Schematic illustration of the sensing mechanism: showing that resistance changes in response to the variation of the contact areas between CNTs, as caused by external forces. e) With the CSFH‐based mechanical sensors, the bending or unbending of fingers can be detected by the brightness of the LED. f) Dissolution of the CSFH in papain solution with concentration of 0.25%.CC BY · PubMed Central
Figure 2 Mechanical properties and sensing performance of CSFH. a) Compression tests on a CSFH film with a thickness of ≈3 mm and an area of 1 cm2. b) The extension test on the CSFH film with a thickness of ≈600 µm, a length of ≈3 cm, and a width of ≈5 mm. The break point shows up at 100% strain. c) I–V curves of the CSFH under different deformations. Electrical resistance response to d) pressure, e) tension strain, and f) bending angles. g) Instant response of the CSFH‐based mechanical sensor, which exhibits a response time of ≈0.1 s. h) Long‐term durability test (1400 s, 5 Hz) of the CSFH‐based mechanical sensor at a pressure of 2 kPa. Inset: magnified view of ten cycles for the early and end stages, respectively.
Figure 2 Mechanical properties and sensing performance of CSFH. a) Compression tests on a CSFH film with a thickness of ≈3 mm and an area of 1 cm2. b) The extension test on the CSFH film with a thickness of ≈600 µm, a length of ≈3 cm, and a width of ≈5 mm. The break point shows up at 100% strain. c) I–V curves of the CSFH under different deformations. Electrical resistance response to d) pressure, e) tension strain, and f) bending angles. g) Instant response of the CSFH‐based mechanical sensor, which exhibits a response time of ≈0.1 s. h) Long‐term durability test (1400 s, 5 Hz) of the CSFH‐based mechanical sensor at a pressure of 2 kPa. Inset: magnified view of ten cycles for the early and end stages, respectively.CC BY · PubMed Central
Figure 3 Degradation/decomposition characteristics of CSFH. a) Schematic diagram showing the controlled degradation mechanism, through adding papain into the CSFH. b) Representative SEM images collected at several stages of degradation for CSFH doped with papain. c) Compressive and tensile modulus of CSFH at different degradation times. d) Resistance response for constant pressure (500 Pa), tension (20%), and bending angle (10°) during degradation. e) Degradation/decomposition rate study at different temperature and pH. The result shows that the degradation rate reaches a maximum at a temperature of 50 °C and a pH of 6. f) Schematic illustration of visible‐light‐triggered degradation of AuNP‐doped CSFH. g) Thermal image of the CSFH treated by two 532 nm lasers with average radiation power of 100 and 50 mW for 5 min. After 1 h of radiation, the irradiated area is completely degraded.
Figure 3 Degradation/decomposition characteristics of CSFH. a) Schematic diagram showing the controlled degradation mechanism, through adding papain into the CSFH. b) Representative SEM images collected at several stages of degradation for CSFH doped with papain. c) Compressive and tensile modulus of CSFH at different degradation times. d) Resistance response for constant pressure (500 Pa), tension (20%), and bending angle (10°) during degradation. e) Degradation/decomposition rate study at different temperature and pH. The result shows that the degradation rate reaches a maximum at a temperature of 50 °C and a pH of 6. f) Schematic illustration of visible‐light‐triggered degradation of AuNP‐doped CSFH. g) Thermal image of the CSFH treated by two 532 nm lasers with average radiation power of 100 and 50 mW for 5 min. After 1 h of radiation, the irradiated area is completely degraded.CC BY · PubMed Central
Figure 4 E‐health monitoring using CSFH‐based mechanical sensors. a) Gesture recognition using 14 CSFH‐based mechanical sensors on every joint of a human hand. Color mapping of the variation in output resistance change, from the 14 CSFH‐based mechanical sensors, can be used for translation of the word “hydrogel”. b) Intracranial pressure (ICP) monitoring by placement of the CSFH‐based pressure sensor in the intracranial space. Upper panel: ICP at normal state and after euthanasia. Bottom panel: Real‐time monitoring of the ICP during an induced epileptic seizure. c) Speech recognition of the words of “ah,” “hello,” and “silk hydrogel”. d) Motion recognition of walking, jogging, and squatting.
Figure 4 E‐health monitoring using CSFH‐based mechanical sensors. a) Gesture recognition using 14 CSFH‐based mechanical sensors on every joint of a human hand. Color mapping of the variation in output resistance change, from the 14 CSFH‐based mechanical sensors, can be used for translation of the word “hydrogel”. b) Intracranial pressure (ICP) monitoring by placement of the CSFH‐based pressure sensor in the intracranial space. Upper panel: ICP at normal state and after euthanasia. Bottom panel: Real‐time monitoring of the ICP during an induced epileptic seizure. c) Speech recognition of the words of “ah,” “hello,” and “silk hydrogel”. d) Motion recognition of walking, jogging, and squatting.CC BY · PubMed Central
Figure 5 CSFH integrating with drug‐loaded silk microneedles to serve as a visible‐light‐triggered drug‐release patch. a) Diagram showing the visible‐light‐triggered drug‐release mechanism of the CSFH plus microneedles patch. b) Photograph of the patch located onto the backside of nude rat. Inset view shows a representative SEM image of the microneedles. c) Flow diagram for visible‐light‐triggered therapy via the patch. d) Thermal image of the patch on the backside of a nude rat after 5 min laser heating. Inset showing a magnified image of the patch and the corresponding temperature profile. e) Epilepsy detection and treatment. After the injection with penicillin G sodium solution for ≈20 min, anesthetized rats start to show intense convulsion symptoms, as represented by sudden large peaks in resistance change. Once the epilepsy symptom is detected, the patch is illuminated by a 532 nm laser with an average radiation power of 100 mW to release drugs for medical treatment. After 10 min of treatment, the rat in the experimental group exhibits effective epilepsy inhibition while the control group continues to have seizures.
Figure 5 CSFH integrating with drug‐loaded silk microneedles to serve as a visible‐light‐triggered drug‐release patch. a) Diagram showing the visible‐light‐triggered drug‐release mechanism of the CSFH plus microneedles patch. b) Photograph of the patch located onto the backside of nude rat. Inset view shows a representative SEM image of the microneedles. c) Flow diagram for visible‐light‐triggered therapy via the patch. d) Thermal image of the patch on the backside of a nude rat after 5 min laser heating. Inset showing a magnified image of the patch and the corresponding temperature profile. e) Epilepsy detection and treatment. After the injection with penicillin G sodium solution for ≈20 min, anesthetized rats start to show intense convulsion symptoms, as represented by sudden large peaks in resistance change. Once the epilepsy symptom is detected, the patch is illuminated by a 532 nm laser with an average radiation power of 100 mW to release drugs for medical treatment. After 10 min of treatment, the rat in the experimental group exhibits effective epilepsy inhibition while the control group continues to have seizures.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

The citation lists are queued

They are fetched later and appear here then.

References 40 · Cited by 120

Research works printed but not linked: 1

  1. Zulli G., 2011, Lat. Am. J. Pharm., 30, 1104

Metadata

Authors
Zhang, S., Zhou, Z., Zhong, J., Shi, Z., Mao, Y., & Tao, T. H.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Shanghai Medical College of Fudan University (CN)
Corresponding author
Tao, Tiger H.
Venue
Advanced Science
Publisher
Wiley
Published
2020-05-11
Volume
7
Issue
13
Pages
1903802-1903802
ISSN
2198-3844 (ISSN-L)
OpenAlex
W3020907512
Cited by
120
References
40
Citations by year
2026: 5 · 2025: 22 · 2024: 23 · 2023: 28 · 2022: 18 · 2021: 17 · 2020: 7
FWCI
5.48
Type
journal article
Language
en
Open access
Locations
  • Advanced Science (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • National Natural Science Foundation of China (61574156, 61904187)
  • Chinese Academy of Sciences (YJKYYQ20170060)
  • National Outstanding Youth Science Fund Project of National Natural Science Foundation of China (61822406)
  • Youth Innovation Promotion Association of the Chinese Academy of Sciences (2019236)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Biomaterials › Silk-based biomaterials and applications
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
silk fibroin hydrogel, conductive hydrogels, wearable sensors, implantable sensors, pressure sensing, strain sensing, epilepsy treatment, local drug delivery, health monitoring, biocompatibility

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Body‐Integrated, Enzyme‐Triggered Degradable, Silk‐Based Mechanical Sensors for Customized Health/Fitness Monitoring and In Situ Treatment. https://app.cochat.ai/papers/10.1002/advs.201903802
The paper
Zhang, S., Zhou, Z., Zhong, J., Shi, Z., Mao, Y., & Tao, T. H. (2020). Body‐Integrated, Enzyme‐Triggered Degradable, Silk‐Based Mechanical Sensors for Customized Health/Fitness Monitoring and In Situ Treatment. Advanced Science. https://doi.org/10.1002/advs.201903802

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.