The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
All‐Hydrocarbon MEA for PEM Water Electrolysis Combining Low Hydrogen Crossover and High Efficiency
Open accessAbstract
Hydrocarbon ionomers bear the potential to significantly lower the material cost and increase the efficiency of proton‐exchange membrane water electrolyzers (PEMWE). However, no fully hydrocarbon membrane electrode assembly (MEA) with a performance comparable to Nafion‐MEAs has been reported. PEMWE‐MEAs are presented comprising sPPS as membrane and electrode binder reaching 3.5 A cm−2 at 1.8 V and thus clearly outperforming state‐of‐the‐art Nafion‐MEAs (N115 as membrane, 1.5 A cm−2 at 1.8 V) due to a significantly lower high frequency resistance (57 ± 4 mΩ cm² vs 161 ± 7 mΩ cm²). Additionally, pure sPPS‐membranes show a three times lower gas crossover (<0.3 mA cm−2) than Nafion N115‐membranes (>1.1 mA cm−2) in a fully humidified surrogate test. Furthermore, more than 80 h of continuous operation is shown for sPPS‐MEAs in a preliminary durability test (constant current hold at 1 A cm−2 at 80 °C). These results rely on the unique transport properties of sulfonated poly(phenylene sulfone) (sPPS) that combines high proton conductivity with low gas crossover.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the development of proton conducting polymer membranes for hydrogen and methanol fuel cells
Kreuer, K. D. (2001) · Journal of Membrane Science · doi:10.1016/s0376-7388(00)00632-3 · Cited by 2,969
Self-citationKreuer, K.-D., Paddison, S. J., Spohr, E., & Schuster, M. (2004) · Chemical Reviews · doi:10.1021/cr020715f · Cited by 2,187
Self-citationEffect of Interfacial Water Transport Resistance on Coupled Proton and Water Transport Across Nafion
Cheah, M. J., Kevrekidis, I. G., & Benziger, J. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp204785t · Cited by 68
Cited by
Recent advances in proton exchange membrane water electrolysis
Liu, R.-T., Xu, Z.-L., Li, F.-M., Chen, F.-Y., Yu, J.-Y., Yan, Y., Chen, Y., & Xia, B. Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00681b · Cited by 701
Stability of electrocatalytic OER: from principle to application
Li, H., Lin, Y., Duan, J., Wen, Q., Liu, Y., & Zhai, T. (2024) · Chemical Society Reviews · doi:10.1039/d3cs00010a · Cited by 540
Status and perspectives of key materials for PEM electrolyzer
Zhang, K., Liang, X., Wang, L., Sun, K., Wang, Y., Xie, Z., Wu, Q., Bai, X., Hamdy, M. S., Chen, H., et al. (2022) · Nano Research Energy · doi:10.26599/nre.2022.9120032 · Cited by 497
Wang, C. R., Stansberry, J. M., Mukundan, R., Chang, H.-M. J., Kulkarni, D., Park, A. M., Plymill, A. B., Firas, N. M., Liu, C. P., Lang, J. T., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00904 · Cited by 402
Salehmin, M. N. I., Husaini, T., Goh, J., & Sulong, A. B. (2022) · Energy Conversion and Management · doi:10.1016/j.enconman.2022.115985 · Cited by 329
Metadata
- Authors
- Klose, C., Saatkamp, T., Münchinger, A., Bohn, L., Titvinidze, G., Breitwieser, M., Kreuer, K., & Vierrath, S.
- Venue
- Advanced Energy Materials
- Publisher
- Wiley
- Published
- 2020-02-25
- Volume
- 10
- Issue
- 14
- ISSN
- 1614-6832 (ISSN-L)
- 1614-6840
- OpenAlex
- W3007780163
- Cited by
- 217
- References
- 3
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.