The DOI matches its Crossref record.
A new fault diagnosis method using fault directions in Fisher discriminant analysis
Abstract
Multivariate statistical methods such as principal component analysis (PCA) and partial least squares (PLS) have been widely applied to the statistical process monitoring (SPM) of chemical processes and their effectiveness for fault detection is well recognized. These methods make use of normal process data to define a tight normal operation region for monitoring. In practice, however, historical process data are often corrupted with faulty data. In this paper, a new process monitoring method is proposed that is composed of three parts: (1) a preanalysis step that first roughly identifies various clusters in a historical data set and then precisely isolates normal and abnormal data clusters by the k‐means clustering method; (2) a fault visualization step that visualizes high‐dimensional data in 2‐D space by performing global Fisher discriminant analysis (FDA), and (3) a new fault diagnosis method based on fault directions in pairwise FDA. A simulation example is used to demonstrate the performance of the proposed fault diagnosis method. An industrial film process is used to illustrate a realistic scenario for data preanalysis, fault visualization, and fault diagnosis. In both examples, the contribution plots method, based on fault directions in pairwise FDA, shows superior capability for fault diagnosis to the contribution plots method based on PCA. © 2005 American Institute of Chemical Engineers AIChE J, 51: 555–571, 2005
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Data-driven Soft Sensors in the process industry
Kadlec, P., Gabrys, B., & Strandt, S. (2009) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2008.12.012 · Cited by 1,845
A Review on Basic Data-Driven Approaches for Industrial Process Monitoring
Yin, S., Ding, S. X., Xie, X., & Luo, H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301773 · Cited by 1,716
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Self-citationYin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294
Data Mining and Analytics in the Process Industry: The Role of Machine Learning
Ge, Z., Song, Z., Ding, S. X., & Huang, B. (2017) · IEEE Access · doi:10.1109/access.2017.2756872 · Cited by 922
“[165] proposed a new fault diagnosis method using fault directions in FDA; Zhang et al.”
Method
Metadata
- Authors
- He, Q. P., Qin, S. J., & Wang, J.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2005-01-13
- Volume
- 51
- Issue
- 2
- Pages
- 555-571
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1983745919
- Cited by
- 250
- References
- 0
- FWCI
- 20.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A new fault diagnosis method using fault directions in Fisher discriminant analysis. https://app.cochat.ai/papers/10.1002/aic.10325
- The paper
- He, Q. P., Qin, S. J., & Wang, J. (2005). A new fault diagnosis method using fault directions in Fisher discriminant analysis. AIChE Journal. https://doi.org/10.1002/aic.10325
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.