The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Gas permeation through DDR‐type zeolite membranes at high temperatures
Abstract
DDR‐type zeolite membranes were prepared by the secondary growth method on porous α‐alumina disk, followed by on‐stream counter diffusion chemical vapor deposition modification to eliminate the intercrystalline micropores. Single gas permeation of He, H 2, CO 2, and CO through this zeolite membrane before and after CVD modification was measured in 25–500°C. Intracrystalline diffusivities for these four gases in DDR‐type zeolite were obtained from the permeation data above 300°C to examine the effects of the size and molecular weight of permeating gases on diffusion and permeation rate for this zeolite membrane. For the unmodified DDR‐type zeolite membrane with presence of a small amount intercrystalline micropores the diffusivity (or permeance) with a low activation energy depends on both the size and molecular weight of permeating gases. For the CVD‐modified DDR‐type zeolite membrane with intercrystalline micropores eliminated, the activation energy for diffusion and diffusivity increases with increasing molecular size of the permeating gases. © 2008 American Institute of Chemical Engineers AIChE J, 2008.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sulfur Dioxide Sorption Properties and Thermal Stability of Hydrophobic Zeolites
Deng, S. G., & Lin, Y. S. (1995) · Industrial & Engineering Chemistry Research · doi:10.1021/ie00038a048 · Cited by 67
Self-citation
Cited by
Metal–organic framework membranes: from synthesis to separation application
Qiu, S., Xue, M., & Zhu, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00159a · Cited by 1,630
Ultrathin, Molecular-Sieving Graphene Oxide Membranes for Selective Hydrogen Separation
Li, H., Song, Z., Zhang, X., Huang, Y., Li, S., Mao, Y., Ploehn, H. J., Bao, Y., & Yu, M. (2013) · Science · doi:10.1126/science.1236686 · Cited by 1,360
Zeolite membranes – a review and comparison with MOFs
Rangnekar, N., Mittal, N., Elyassi, B., Caro, J., & Tsapatsis, M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00292c · Cited by 735
Molecular Sieve Membrane: Supported Metal–Organic Framework with High Hydrogen Selectivity
Li, Y., Liang, F., Bux, H., Feldhoff, A., Yang, W., & Caro, J. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905645 · Cited by 645
Porous Inorganic Membranes for CO2 Capture: Present and Prospects
Pera-Titus, M. (2014) · Chemical Reviews · doi:10.1021/cr400237k · Cited by 614
Metadata
- Authors
- Kanezashi, M., O'Brien‐Abraham, J., Lin, Y. S., & Suzuki, K.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2008-04-22
- Volume
- 54
- Issue
- 6
- Pages
- 1478-1486
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2066438297
- Cited by
- 213
- References
- 1
- FWCI
- 24.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.