Heat transfer and frost formation inside a liquid nitrogen‐cooled tube
Abstract
An experimental study was undertaken of simultaneous heat transfer and frost deposition inside a liquid nitrogen‐cooled tube for a range of humidities and Reynolds numbers. The data indicate that diffusion of water vapor within the frost layer caused the frost density and thermal conductivity to increase with time. The increase was so great that the heat transfer rate became constant even while frost continued to accumulate. In a separate study the thermal conductivities of frosts formed on a cryogenic surface were measured and found to be lower than values near the freezing point of water.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The trend of increasing pressure loss coefficient with initial air velocity is consistent with previous reports [28,29].
“This is consistent with previous reports [28,29].”
From Performance prediction of a fin-and-tube heat exchanger considering air-flow reduction due to the frost accumulation (2013) · cites this paper as [28]
Cited by
Sorted by citations
Ye, H.-Y., & Lee, K.-S. (2013) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2013.08.026 · Cited by 70 · see citing works
- Authors
- Reid, R. C., Brian, P. L. T., & Weber, M. E.
- Affiliations
- Massachusetts Institute of Technology (US)
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1966-11
- Volume
- 12
- Issue
- 6
- Pages
- 1190-1195
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2049706230
- Cited by
- 10
- References
- 0
- Citations by year
- 2026: 1 · 2019: 2 · 2013: 1
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- AIChE Journal (publishedVersion)
- Funders
- National Science Foundation
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Aerospace Engineering › Icing and De-icing Technologies
- Keywords
- frost formation, heat transfer, liquid nitrogen cooling, cryogenic surfaces, water vapor diffusion, frost density, humidity effects, Reynolds number effects, frost layer growth
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review