Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record.

Gas‐holdup measurements in bubble columns using computed tomography

Kumar, Sailesh B., Moslemian, Davood, Duduković, Milorad P. · 1997 · AIChE Journal

Abstract

A computed tomographic scanner was developed for imaging gas‐holdup distributions in two‐phase flow systems such as bubble columns and fluidized beds. The scanner has been used to study the effects of various operating parameters (such as column diameter, superficial gas velocity, and distributor type) on the gas holdup and its distribution in an air–water bubble column. The experimental investigation shows that the column dimensions have no significant effect on the void fraction when the column diameter is greater than 0.15 m. Differences in the holdup distribution due to the kind of distributor used are significant only at low gas flow rates. Surface tension of the liquid has a profound influence on the gas holdup and its distribution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/aic.690430605

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
Kumar, S. B., Moslemian, D., & Duduković, M. P.
Venue
AIChE Journal
Publisher
Wiley
Published
1997-06
Volume
43
Issue
6
Pages
1414-1425
ISSN
  • 0001-1541 (ISSN-L)
  • 1547-5905
OpenAlex
W2164803679
Cited by
186
References
0
FWCI
5.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Gas‐holdup measurements in bubble columns using computed tomography. https://app.cochat.ai/papers/10.1002/aic.690430605
The paper
Kumar, S. B., Moslemian, D., & Duduković, M. P. (1997). Gas‐holdup measurements in bubble columns using computed tomography. AIChE Journal. https://doi.org/10.1002/aic.690430605

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.