Performance analysis of four‐bed H2 PSA process using layered beds
The DOI matches its Crossref record.
Abstract
Hydrogen purification from a typical cracked gas mixture (H 2/CO 2/CH 4/CO) by the four‐bed PSA process was studied experimentally and theoretically using layered bed of activated carbon and zeolite 5A. The mathematical model accounts for the mass and heat transfer resistance using the linear driving force approximation for the particle uptake, and the ideal adsorbed solution model represents the multicomponent adsorption equilibrium. Effects of the superficial velocity, heat transfer resistance and the bed layering on the process performance were investigated. Since the recovery sharply decreases above a certain productivity at the given purity, the relation between the productivity and recovery was studied before the process design. Its performance decreased with the increase in heat transfer resistance, but increased with heat transfer resistance in some range. Both the experiment and theory showed optimum carbon‐to‐zeolite ratios. Those optimum ratios depend on such operating variables as the superficial velocity, heat transfer resistance and product purity. For higher product purity more zeolite was used. As the superficial velocity increased, the process performance has its maximum at higher carbon‐to‐zeolite ratio. Except for the adiabatic conditions, the optimum carbon‐to‐zeolite ratio increased with the increase in the heat transfer resistance. At the adiabatic conditions, however, the optimum carbon‐to‐zeolite ratio was lower than that at the nonisothermal conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ben-Mansour, R., Habib, M. A., Bamidele, O. E., Basha, M., Qasem, N. A. A., Peedikakkal, A., Laoui, T., & Ali, M. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.10.011 · Cited by 722
A review of mathematical modeling of fixed-bed columns for carbon dioxide adsorption
Shafeeyan, M. S., Wan Daud, W. M. A., & Shamiri, A. (2014) · Chemical Engineering Research and Design · doi:10.1016/j.cherd.2013.08.018 · Cited by 293
Advances in Pressure Swing Adsorption for Gas Separation
Grande, C. A. (2012) · ISRN Chemical Engineering · doi:10.5402/2012/982934 · Cited by 285
“[68] J.”
BackgroundA parametric study of layered bed PSA for hydrogen purification
Ribeiro, A. M., Grande, C. A., Lopes, F. V. S., Loureiro, J. M., & Rodrigues, A. E. (2008) · Chemical Engineering Science · doi:10.1016/j.ces.2008.07.017 · Cited by 233
Ben-Mansour, R., & Qasem, N. A. A. (2018) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.11.010 · Cited by 139
Metadata
- Authors
- Park, J., Kim, J., & Cho, S.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2000-04
- Volume
- 46
- Issue
- 4
- Pages
- 790-802
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2031773285
- Cited by
- 90
- References
- 0
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance analysis of four‐bed H2 PSA process using layered beds. https://app.cochat.ai/papers/10.1002/aic.690460413
- The paper
- Park, J., Kim, J., & Cho, S. (2000). Performance analysis of four‐bed H2 PSA process using layered beds. AIChE Journal. https://doi.org/10.1002/aic.690460413
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.