The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Monitoring independent components for fault detection
Abstract
A chemical process has a large number of measured variables, but it is usually driven by fewer essential variables, which may or may not be measured. Extracting such essential variables and monitoring them will improve the process‐monitoring performance. Independent component analysis (ICA) is an emerging technique for finding several independent variables as linear combinations of measured variables. In this work, a new statistical process control method based on ICA is proposed. For investigating the feasibility of its method, its fault‐detection performance is evaluated and compared with that of the conventional multivariate statistical process control (cMSPC) method using principal‐component analysis by applying those methods to monitoring problems of a simple four‐variable system and a continuous‐stirred‐tank‐reactor process. The simulated results show the superiority of ICA‐based SPC over cMSPC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Statistical Quality Control
Sauter, R. M., & Montgomery, D. C. (1992) · Technometrics · doi:10.2307/1269251 · Cited by 7,842
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Blind separation of sources, part I: An adaptive algorithm based on neuromimetic architecture
Jutten, C., & Herault, J. (1991) · Signal Processing · doi:10.1016/0165-1684(91)90079-x · Cited by 2,521
Disturbance detection and isolation by dynamic principal component analysis
Ku, W., Storer, R. H., & Georgakis, C. (1995) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/0169-7439(95)00076-3 · Cited by 1,483
Control Procedures for Residuals Associated With Principal Component Analysis
Jackson, J. E., & Mudholkar, G. S. (1979) · Technometrics · doi:10.1080/00401706.1979.10489779 · Cited by 1,237
Multivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989
Multiscale PCA with application to multivariate statistical process monitoring
Bakshi, B. R. (1998) · AIChE Journal · doi:10.1002/aic.690440712 · Cited by 839
Process monitoring and diagnosis by multiblock PLS methods
MacGregor, J. F., Jaeckle, C., Kiparissides, C., & Koutoudi, M. (1994) · AIChE Journal · doi:10.1002/aic.690400509 · Cited by 773
Multi‐way principal components‐and PLS‐analysis
Wold, S., Geladi, P., Esbensen, K., & Öhman, J. (1987) · Journal of Chemometrics · doi:10.1002/cem.1180010107 · Cited by 748
Adaptive blind separation of independent sources: A deflation approach
Delfosse, N., & Loubaton, P. (1995) · Signal Processing · doi:10.1016/0165-1684(95)00042-c · Cited by 499
Cited by
A Review on Basic Data-Driven Approaches for Industrial Process Monitoring
Yin, S., Ding, S. X., Xie, X., & Luo, H. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301773 · Cited by 1,716
Survey on data-driven industrial process monitoring and diagnosis
Qin, S. J. (2012) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2012.09.004 · Cited by 1,470
Yin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294
Review of Recent Research on Data-Based Process Monitoring
Ge, Z., Song, Z., & Gao, F. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie302069q · Cited by 967
Data Mining and Analytics in the Process Industry: The Role of Machine Learning
Ge, Z., Song, Z., Ding, S. X., & Huang, B. (2017) · IEEE Access · doi:10.1109/access.2017.2756872 · Cited by 922
“[55].”
Metadata
- Authors
- Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2003-04
- Volume
- 49
- Issue
- 4
- Pages
- 969-976
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2125568459
- Cited by
- 410
- References
- 13
- FWCI
- 20.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring independent components for fault detection. https://app.cochat.ai/papers/10.1002/aic.690490414
- The paper
- Kano, M., Tanaka, S., Hasebe, S., Hashimoto, I., & Ohno, H. (2003). Monitoring independent components for fault detection. AIChE Journal. https://doi.org/10.1002/aic.690490414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.