The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Voidage variation in packed beds at small column to particle diameter ratio
Abstract
Randomly packed beds of equal spheres exhibit damped oscillatory voidage variation in the near wall region. Models reported in literature were found to be lacking in their ability to relate this variation to average bed porosity. The changing mean of the voidage oscillations and deviations from sinusoidal behavior were not described well either. Experimental data and a new radial bed porosity model are presented. Improved radial bed voidage and average bed voidage predictions were demonstrated. It has further been shown that multiple stable packing configurations exist within the same packing mode, which complicates modeling at a small column to particle diameter ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluid flow through granular beds
Carman, P. C. (1997) · Chemical Engineering Research and Design · doi:10.1016/s0263-8762(97)80003-2 · Cited by 3,300
Void fraction distribution in beds of spheres
Benenati, R. F., & Brosilow, C. B. (1962) · AIChE Journal · doi:10.1002/aic.690080319 · Cited by 671
Radial Distribution of the Random Close Packing of Equal Spheres
SCOTT, G. D. (1962) · Nature · doi:10.1038/194956a0 · Cited by 344
Radial porosity variations in packed beds
Roblee, L. H. S., Baird, R. M., & Tierney, J. W. (1958) · AIChE Journal · doi:10.1002/aic.690040415 · Cited by 332
Evaluation of steady flow profiles in rectangular and circular packed beds by a variational method
Vortmeyer, D., & Schuster, J. (1983) · Chemical Engineering Science · doi:10.1016/0009-2509(83)85026-x · Cited by 311
Low peclet number particle-to-fluid heat and mass transfer in packed beds
Martin, H. (1978) · Chemical Engineering Science · doi:10.1016/0009-2509(78)85181-1 · Cited by 283
Mueller, G. E. (1992) · Powder Technology · doi:10.1016/0032-5910(92)80045-x · Cited by 275
Measured and modeled superficial flow profiles in packed beds with liquid flow
Giese, M., Rottschäfer, K., & Vortmeyer, D. (1998) · AIChE Journal · doi:10.1002/aic.690440225 · Cited by 262
Wall effects in laminar flow of fluids through packed beds
Cohen, Y., & Metzner, A. B. (1981) · AIChE Journal · doi:10.1002/aic.690270502 · Cited by 235
Structural properties of packed beds — A review
Haughey, D. P., & Beveridge, G. S. G. (1969) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450470206 · Cited by 229
Cited by
Review on the structure of random packed‐beds
von Seckendorff, J., & Hinrichsen, O. (2021) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.23959 · Cited by 110
Medical oxygen concentrators: a review of progress in air separation technology
Ackley, M. W. (2019) · Adsorption · doi:10.1007/s10450-019-00155-w · Cited by 89
Metadata
- Authors
- de Klerk, A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2003-08
- Volume
- 49
- Issue
- 8
- Pages
- 2022-2029
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2082407888
- Cited by
- 419
- References
- 24
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Voidage variation in packed beds at small column to particle diameter ratio. https://app.cochat.ai/papers/10.1002/aic.690490812
- The paper
- de Klerk, A. (2003). Voidage variation in packed beds at small column to particle diameter ratio. AIChE Journal. https://doi.org/10.1002/aic.690490812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.