CoChat

Hydroxyurea (HU) for prevention of recurrent stroke in sickle cell anemia (SCA)

Open access
Sumoza, Abraham, de Bisotti, Renate, Sumoza, David, Fairbanks, Virgil · 2002 · American Journal of Hematology
Cited by 74

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Cerebrovascular accident (CVA) is a major cause of morbidity and death in sickle cell anemia (SCA). Transfusion of packed erythrocytes is widely used to prevent this complication. However, chronic transfusion may lead to iron overload, alloimmunization, or infections. Cost and compliance may compromise transfusion therapy. A possible alternative, the prophylactic use of hydroxyurea (HU), has not been tried to determine whether it may prevent recurrent stroke. We used HU in five children with SCA who had suffered stroke, in three of them after a first episode and in the other two after a second CVA. Four had infarctive stroke and one a transient ischemic attack (TIA). Four patients took HU at a dose of 40 mg/kg/d, one patient at 30 mg/kg/d. None of the patients had recurrent stroke during 42–112 months of observation. None experienced pain crises. In all, HbF increased significantly and was maintained above 14.7% during treatment. The total Hb concentration increased 19.5 g/L (median) above the value before treatment. HU was well tolerated. None of the five children had leukopenia or thrombocytopenia during therapy. HU appears to prevent recurrence of stroke in SCA without risk of major toxicity. Am. J. Hematol. 71:161–165, 2002. © 2002 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ajh.10205

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Sumoza, A., de Bisotti, R., Sumoza, D., & Fairbanks, V.
Venue
American Journal of Hematology
Publisher
Wiley
Published
2002-10-30
Volume
71
Issue
3
Pages
161-165
ISSN
  • 0361-8609 (ISSN-L)
  • 1096-8652
OpenAlex
W2077824941
Cited by
74
References
7
FWCI
2.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.