Safety and efficacy of total dose infusion of 1,020 mg of ferumoxytol administered over 15 min
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For the majority of patients with iron deficiency anemia (IDA), a full course of intravenous (IV) iron is 1 g. Most IV irons require 5–10 administrations of 100–300 mg. We have successfully employed 1 g low molecular weight iron dextran over 1 hr. For further convenience for patients and physicians, we explored the administration of 1.02 g of ferumoxytol over 15 min instead of the approved 2 × 510 mg injections. Sixty patients with IDA, (hemoglobin <11 g/dL, transferrin saturation [TSAT] ≤20%, and ferritin <100 ng/mL) with an inadequate response or intolerance to oral iron, received 1020 mg ferumoxytol over 15 min. Vital signs were measured for 1 hr. Adverse events (AEs) were collected via telephone at 1, 2, and 7 days. Follow‐up visits occurred at 4 and 8 weeks for efficacy assessments. The primary endpoint was safety and tolerability. Secondary efficacy endpoints included mean change in hemoglobin, TSAT, and red cell distribution width. No serious adverse events (SAEs) occurred. Fifty‐eight patients received the planned dose. Twenty‐six out of sixty (43.3%) patients reported AEs of which 13 were mild and transient during infusion. All resolved within minutes. Fourteen patients reported self‐limited arthralgias, myalgias, and/or headache within 24–48 hr. At Baseline, the mean hemoglobin was 9.4 g/dL. The mean increments at Week 4 and 8 were 2.1 and 2.6 g/dL, respectively. Ferumoxytol, administered as 1.02 g infusion over 15 min was well tolerated with no SAEs and demonstrated excellent efficacy. If corroborated in future studies this represents an improved method of treating IDA. Am. J. Heamtol. 88:944–947, 2013. © 2013 The Authors. American Journal of Hematology published by Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jahn, M. R., Andreasen, H. B., Fütterer, S., Nawroth, T., Schünemann, V., Kolb, U., Hofmeister, W., Muñoz, M., Bock, K., Meldal, M., et al. (2011) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2011.03.016 · Cited by 256
Cited by
Camaschella, C. (2015) · New England Journal of Medicine · doi:10.1056/nejmra1401038 · Cited by 1,678
Berger, M. M., Shenkin, A., Schweinlin, A., Amrein, K., Augsburger, M., Biesalski, H.-K., Bischoff, S. C., Casaer, M. P., Gundogan, K., Lepp, H.-L., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.02.015 · Cited by 615
Macdougall, I. C., Bircher, A. J., Eckardt, K.-U., Obrador, G. T., Pollock, C. A., Stenvinkel, P., Swinkels, D. W., Wanner, C., Weiss, G., Chertow, G. M., et al. (2016) · Kidney International · doi:10.1016/j.kint.2015.10.002 · Cited by 482
Self-citationHow we diagnose and treat iron deficiency anemia
Auerbach, M., & Adamson, J. W. (2016) · American Journal of Hematology · doi:10.1002/ajh.24201 · Cited by 308
Self-citationDeLoughery, T. G. (2017) · Medical Clinics of North America · doi:10.1016/j.mcna.2016.09.004 · Cited by 231
Metadata
- Authors
- Auerbach, M., Strauss, W., Auerbach, S., Rineer, S., & Bahrain, H.
- Venue
- American Journal of Hematology
- Publisher
- Wiley
- Published
- 2013-09-09
- Volume
- 88
- Issue
- 11
- Pages
- 944-947
- ISSN
- 0361-8609 (ISSN-L)
- 1096-8652
- OpenAlex
- W2053485995
- Cited by
- 74
- References
- 1
- FWCI
- 5.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.