Comparison of ultrasound and skinfold measurements in assessment of subcutaneous and total fatness
The DOI matches its Crossref record.
Abstract
Ultrasound (A‐scan mode) and skinfold methods were evaluated in the measurement of subcutaneous fat thickness and prediction of total fat weight (by whole body potassium counting). Based on intraobserver correlations on 39 men at 15 body sites, skinfold caliper measurements were more reproducible than ones obtained by ultrasound. Measurements made with the two techniques at the same site typically produced different mean estimates of fat thickness. However, scores were often highly correlated with each other, indicating similar relative rankings of subjects by each technique. Skinfolds were more highly correlated with total fat weight than were ultrasound measurements, but body weight and anthropometric measures had even higher correlations with total fat weight. Anthropometric measurements were highly correlated with fatness because of their association with body weight, and when this relationship was statistically controlled for, they typically lost their predictive effectiveness. Multiple regression analyses revealed that the best predictors of fat weight were body weight along with skinfold and ultrasound measurements. These results suggest that skinfolds are a more effective means of assessing subcutaneous fat than ultrasound, especially when the large difference in cost of equipment is considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Methods for the assessment of human body composition: traditional and new
Lukaski, H. C. (1987) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/46.4.537 · Cited by 1,152
Assessment of abdominal fat content by computed tomography
Borkan, G., Gerzof, S., Robbins, A., Hults, D., Silbert, C., & Silbert, J. (1982) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/36.1.172 · Cited by 491
Self-citationAging and Imaging Assessment of Body Composition: From Fat to Facts
Ponti, F., Santoro, A., Mercatelli, D., Gasperini, C., Conte, M., Martucci, M., Sangiorgi, L., Franceschi, C., & Bazzocchi, A. (2020) · Frontiers in Endocrinology · doi:10.3389/fendo.2019.00861 · Cited by 408
Abate, N., Burns, D., Peshock, R. M., Garg, A., & Grundy, S. M. (1994) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)40090-2 · Cited by 339
Omran, M. L., & Morley, J. E. (2000) · Nutrition · doi:10.1016/s0899-9007(99)00224-5 · Cited by 318
Metadata
- Authors
- Borkan, G. A., Hults, D. E., Cardarelli, J., & Burrows, B. A.
- Venue
- American Journal of Physical Anthropology
- Publisher
- Wiley
- Published
- 1982-07
- Volume
- 58
- Issue
- 3
- Pages
- 307-313
- ISSN
- 0002-9483 (ISSN-L)
- 1096-8644
- OpenAlex
- W1976499525
- Cited by
- 105
- References
- 0
- FWCI
- 4.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of ultrasound and skinfold measurements in assessment of subcutaneous and total fatness. https://app.cochat.ai/papers/10.1002/ajpa.1330580309
- The paper
- Borkan, G. A., Hults, D. E., Cardarelli, J., & Burrows, B. A. (1982). Comparison of ultrasound and skinfold measurements in assessment of subcutaneous and total fatness. American Journal of Physical Anthropology. https://doi.org/10.1002/ajpa.1330580309
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.