CoChat

Prediction of hemorrhagic transformation after recanalization therapy using T2*‐permeability magnetic resonance imaging

Bang, Oh Young, Buck, Brian H., Saver, Jeffrey L., Alger, Jeffry R., Yoon, Sa Rah, Starkman, Sidney, Ovbiagele, Bruce, Kim, Doojin, Ali, Latisha K., Sanossian, Nerses, Jahan, Reza, Duckwiler, Gary R., Viñuela, Fernando, Salamon, Noriko, Villablanca, J. Pablo, Liebeskind, David S. · 2007 · Annals of Neurology
Cited by 148

The DOI matches its Crossref record.

Abstract

Objective: Predicting hemorrhagic transformation (HT) is critical in the setting of recanalization therapy for acute stroke. Dedicated magnetic resonance imaging (MRI) sequences for detection of increased blood–brain barrier (BBB) permeability recently have been developed. We evaluated the ability of a novel MRI permeability technique to detect baseline derangements predictive of various forms of HT after recanalization therapy. Methods: We retrospectively analyzed the clinical and pretreatment MRI data on patients undergoing recanalization therapy for acute cerebral ischemia at a university medical center from January 2004 to November 2006. Pretreatment MRI permeability images derived from perfusion source data were compared with posttreatment imaging to evaluate whether baseline BBB permeability derangements may predict HT after recanalization therapy. The use of a novel permeability technique to illustrate BBB derangements was based on the detection of decreased signal intensity at later time points in perfusion MRI acquisition, signifying continued local accumulation of contrast caused by leakage. Results: Among 32 patients, some degree of HT occurred in 12. Permeability image abnormalities at baseline were present in 7 of 12 patients with HT and none of the 20 patients without HT on follow‐up images. The sensitivity of permeability abnormality for parenchymal hematoma was 83%. False‐negative findings were noted in five cases, most commonly asymptomatic or minor HT after mechanical clot retrieval. Interpretation: Permeability images derived from pretreatment perfusion MRI source data may identify patients at risk for HT with high specificity. Our preliminary demonstration of permeability imaging based on standard perfusion data for prediction of hemorrhage merits further study with dedicated MRI BBB permeability acquisitions and multicenter validation. Ann Neurol 2007

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.21174

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 148

Metadata

Authors
Bang, O. Y., Buck, B. H., Saver, J. L., Alger, J. R., Yoon, S. R., Starkman, S., Ovbiagele, B., Kim, D., Ali, L. K., Sanossian, N., Jahan, R., Duckwiler, G. R., Viñuela, F., Salamon, N., Villablanca, J. P., & Liebeskind, D. S.
Venue
Annals of Neurology
Publisher
Wiley
Published
2007-08
Volume
62
Issue
2
Pages
170-176
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2054789729
Cited by
148
References
0
FWCI
7.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prediction of hemorrhagic transformation after recanalization therapy using T2*‐permeability magnetic resonance imaging. https://app.cochat.ai/papers/10.1002/ana.21174
The paper
Bang, O. Y., Buck, B. H., Saver, J. L., Alger, J. R., Yoon, S. R., Starkman, S., Ovbiagele, B., Kim, D., Ali, L. K., Sanossian, N., Jahan, R., Duckwiler, G. R., Viñuela, F., Salamon, N., Villablanca, J. P., & Liebeskind, D. S. (2007). Prediction of hemorrhagic transformation after recanalization therapy using T2*‐permeability magnetic resonance imaging. Annals of Neurology. https://doi.org/10.1002/ana.21174

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.