Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial

Molina, Carlos A., Barreto, Andrew D., Tsivgoulis, Georgios, Sierzenski, Paul, Malkoff, Marc D., Rubiera, Marta, Gonzales, Nicole, Mikulik, Robert, Pate, Greg, Ostrem, James, Singleton, Walter, Manvelian, Garen, Unger, Evan C., Grotta, James C., Schellinger, Peter D., Alexandrov, Andrei V.·2009·Annals of Neurology

Abstract

Objective: Microspheres (μS) reach intracranial occlusions and transmit energy momentum from an ultrasound wave to residual flow to promote recanalization. We report a randomized multicenter phase II trial of μS dose escalation with systemic thrombolysis. Methods: Stroke patients receiving 0.9mg/kg tissue plasminogen activator (tPA) with pretreatment proximal intracranial occlusions on transcranial Doppler (TCD) were randomized (2:1 ratio) to μS (MRX‐801) infusion over 90 minutes (Cohort 1, 1.4ml; Cohort 2, 2.8ml) with continuous TCD insonation, whereas controls received tPA and brief TCD assessments. The primary endpoint was symptomatic intracerebral hemorrhage (sICH) within 36 hours after tPA. Results: Among 35 patients (Cohort 1 = 12, Cohort 2 = 11, controls = 12) no sICH occurred in Cohort 1 and controls, whereas 3 (27%, 2 fatal) sICHs occurred in Cohort 2 (p = 0.028). Sustained complete recanalization/clinical recovery rates (end of TCD monitoring/3 month) were 67%/75% for Cohort 1, 46%/50% for Cohort 2, and 33%/36% for controls (p = 0.255/0.167). The median time to any recanalization tended to be shorter in Cohort 1 (30 min; interquartile range [IQR], 6) and Cohort 2 (30 min; IQR, 69) compared to controls (60 min; IQR, 5; p = 0.054). Although patients with sICH had similar screening and pretreatment systolic blood pressure (SBP) levels in comparison to the rest, higher SBP levels were documented in sICH+ patients at 30 minutes, 60 minutes, 90 minutes, and 24–36 hours following tPA bolus. Interpretation: Perflutren lipid μS can be safely combined with systemic tPA and ultrasound at a dose of 1.4ml. Safety concerns in the second dose tier may necessitate extended enrollment and further experiments to determine the mechanisms by which microspheres interact with tissues. In both dose tiers, sonothrombolysis with μS and tPA shows a trend toward higher early recanalization and clinical recovery rates compared to standard intravenous tPA therapy. Ann Neurol 2009;66:28–38

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.21723

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Molina, C. A., Barreto, A. D., Tsivgoulis, G., Sierzenski, P., Malkoff, M. D., Rubiera, M., Gonzales, N., Mikulik, R., Pate, G., Ostrem, J., Singleton, W., Manvelian, G., Unger, E. C., Grotta, J. C., Schellinger, P. D., & Alexandrov, A. V.
Venue
Annals of Neurology
Publisher
Wiley
Published
2009-07
Volume
66
Issue
1
Pages
28-38
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2061896383
Cited by
230
References
0
FWCI
16.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial. https://app.cochat.ai/papers/10.1002/ana.21723
The paper
Molina, C. A., Barreto, A. D., Tsivgoulis, G., Sierzenski, P., Malkoff, M. D., Rubiera, M., Gonzales, N., Mikulik, R., Pate, G., Ostrem, J., Singleton, W., Manvelian, G., Unger, E. C., Grotta, J. C., Schellinger, P. D., & Alexandrov, A. V. (2009). Transcranial ultrasound in clinical sonothrombolysis (TUCSON) trial. Annals of Neurology. https://doi.org/10.1002/ana.21723

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.