CoChat

Classification Accuracy of Transcranial Magnetic Stimulation for the Diagnosis of Neurodegenerative Dementias

Open access
Benussi, Alberto, Grassi, Mario, Palluzzi, Fernando, Koch, Giacomo, Di Lazzaro, Vincenzo, Nardone, Raffaele, Cantoni, Valentina, Dell'Era, Valentina, Premi, Enrico, Martorana, Alessandro, di Lorenzo, Francesco, Bonnì, Sonia, Ranieri, Federico, Capone, Fioravante, Musumeci, Gabriella, Cotelli, Maria Sofia, Padovani, Alessandro, Borroni, Barbara · 2020 · Annals of Neurology
Cited by 91

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Objective: Transcranial magnetic stimulation (TMS) has been suggested as a reliable, noninvasive, and inexpensive tool for the diagnosis of neurodegenerative dementias. In this study, we assessed the classification performance of TMS parameters in the differential diagnosis of common neurodegenerative disorders, including Alzheimer disease (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD). Methods: We performed a multicenter study enrolling patients referred to 4 dementia centers in Italy, in accordance with the Standards for Reporting of Diagnostic Accuracy. All patients underwent TMS assessment at recruitment (index test), with application of reference clinical criteria, to predict different neurodegenerative disorders. The investigators who performed the index test were masked to the results of the reference test and all other investigations. We trained and tested a random forest classifier using 5‐fold cross‐validation. The primary outcome measures were the classification accuracy, precision, recall, and F1 score of TMS in differentiating each neurodegenerative disorder. Results: A total of 694 participants were included, namely 273 patients diagnosed as AD, 67 as DLB, and 207 as FTD, and 147 healthy controls (HC). A series of 3 binary classifiers was employed, and the prediction model exhibited high classification accuracy (ranging from 0.89 to 0.92), high precision (0.86–0.92), high recall (0.93–0.98), and high F1 scores (0.89–0.95) in differentiating each neurodegenerative disorder. Interpretation: TMS is a noninvasive procedure that reliably and selectively distinguishes AD, DLB, FTD, and HC, representing a useful additional screening tool to be used in clinical practice. Ann Neurol 2020;87:394–404

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.25677

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 91

Metadata

Authors
Benussi, A., Grassi, M., Palluzzi, F., Koch, G., Di Lazzaro, V., Nardone, R., Cantoni, V., Dell'Era, V., Premi, E., Martorana, A., di Lorenzo, F., Bonnì, S., Ranieri, F., Capone, F., Musumeci, G., Cotelli, M. S., Padovani, A., & Borroni, B.
Venue
Annals of Neurology
Publisher
Wiley
Published
2020-01-23
Volume
87
Issue
3
Pages
394-404
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W3000064280
Cited by
91
References
12
FWCI
5.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Classification Accuracy of Transcranial Magnetic Stimulation for the Diagnosis of Neurodegenerative Dementias. https://app.cochat.ai/papers/10.1002/ana.25677
The paper
Benussi, A., Grassi, M., Palluzzi, F., Koch, G., Di Lazzaro, V., Nardone, R., Cantoni, V., Dell'Era, V., Premi, E., Martorana, A., di Lorenzo, F., Bonnì, S., Ranieri, F., Capone, F., Musumeci, G., Cotelli, M. S., Padovani, A., & Borroni, B. (2020). Classification Accuracy of Transcranial Magnetic Stimulation for the Diagnosis of Neurodegenerative Dementias. Annals of Neurology. https://doi.org/10.1002/ana.25677

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.