The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The Quartz Microbalance: A Novel Approach to the In‐Situ Investigation of Interfacial Phenomena at the Solid/Liquid Junction [New Analytical Methods (40)]
Abstract
When Archimedes was asked by King Hiero of Syracuse to prove whether a handcrafted crown really consisted of pure gold and not of gold with a proportion silver, he immersed the crown and an equal weight of pure gold, both attached to a beam balance, into a vessel of water. We all know that according to Archimedes's principle the scale beam rose on the side the crown was attached proving that the goldsmith had intermingled some silver. In spite of the simplicity of this experiment, the result convincingly demonstrates the physical integrity of this classical approach which is based on a weighing procedure. The mass sensitive technique we shall report on in this article is based on the principle that a shift in the resonance frequency of an oscillating AT‐cut quartz disk can be correlated quantitatively with a change in mass in the nanogram range. One side of the quartz disk is in contact with a liquid, while the other side remains exposed to the atmosphere. The changes in weight involved in testing Hiero's crown were probably several hundred grams which corresponds to about 10 25 water molecules. By applying the quartz microbalance, e.g., to solvent migration through thin films, one can sense entrapment of water with a resolution down to 10 14 molecules per unit surface area. If adsorbate layers are in question, fractional coverages down to 0.02 monolayers can be monitored, which only goes to prove the capability of this instrument for investigating interfacial processes on a microscopic level. The option of recording charge flux and interfacial capacitance along with the mass change makes this instrument a powerful in‐situ tool for scientific and technological applications in many fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
The oscillation frequency of a quartz resonator in contact with liquid
Kanazawa, K. K., & Gordon, J. G. (1985) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82721-x · Cited by 1,316
Frequency shifts of piezoelectric quartz crystals immersed in organic liquids
NOMURA, T., & OKUHARA, M. (1982) · Analytica Chimica Acta · doi:10.1016/s0003-2670(01)95290-0 · Cited by 347
Schultze, J. W., & Koppitz, F. D. (1976) · Electrochimica Acta · doi:10.1016/0013-4686(76)85022-0 · Cited by 221
Characterization of acid-base properties of the hydrated oxides on iron and titanium metal surfaces
Simmons, G. W., & Beard, B. C. (1987) · The Journal of Physical Chemistry · doi:10.1021/j100289a025 · Cited by 179
Underpotential metal deposition on gold, monitored in situ with a quartz microbalance
Deakin, M. R., & Melroy, O. (1988) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(88)80288-2 · Cited by 166
In-plane structure of underpotentially deposited copper on gold(111) determined by surface EXAFS
Melroy, O. R., Samant, M. G., Borges, G. L., Gordon, J. G., Blum, L., White, J. H., Albarelli, M. J., McMillan, M., & Abruña, H. D. (1988) · Langmuir · doi:10.1021/la00081a039 · Cited by 156
Study of underpotentially deposited copper on gold by fluorescence detected surface EXAFS
Blum, L., Abruña, H. D., White, J., Gordon, J. G., Borges, G. L., Samant, M. G., & Melroy, O. R. (1986) · The Journal of Chemical Physics · doi:10.1063/1.451404 · Cited by 148
Direct determination of the mass of an underpotentially deposited monolayer of lead on gold
Melroy, O. R., Kanazawa, K. K., Gordon, J. G., & Buttry, D. A. (1986) · Langmuir · doi:10.1021/la00072a003 · Cited by 138
Structural investigation by infra-red spectroscopy of adsorbed hydrogen on platinum
Bewick, A., & Russell, J. W. (1982) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(82)85029-8 · Cited by 137
Cited by
Molecular Self-Assembly and Nanochemistry: a Chemical Strategy for the Synthesis of Nanostructures
Whitesides, G. M., Mathias, J. P., & Seto, C. T. (1991) · Science · doi:10.1126/science.1962191 · Cited by 3,632
Electrochemical Biosensors - Sensor Principles and Architectures
Grieshaber, D., MacKenzie, R., Vörös, J., & Reimhult, E. (2008) · Sensors · doi:10.3390/s80314000 · Cited by 2,329
Reviakine, I., Johannsmann, D., & Richter, R. P. (2011) · Analytical Chemistry · doi:10.1021/ac201778h · Cited by 871
Metal Hexacyanoferrates: Electrosynthesis, in Situ Characterization, and Applications
de Tacconi, N. R., Rajeshwar, K., & Lezna, R. O. (2003) · Chemistry of Materials · doi:10.1021/cm0341540 · Cited by 460
Ostuni, E., Yan, L., & Whitesides, G. M. (1999) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/s0927-7765(99)00004-1 · Cited by 453
Thickness-shear-mode acoustic wave sensors in the liquid phase. A review
Thompson, M., Kipling, A. L., Duncan-Hewitt, W. C., Rajaković, L. V., & Čavić-Vlasak, B. A. (1991) · The Analyst · doi:10.1039/an9911600881 · Cited by 324
Johannsmann, D. (2008) · Physical Chemistry Chemical Physics · doi:10.1039/b803960g · Cited by 297
Single-Molecule Electron Transfer in Electrochemical Environments
Zhang, J., Kuznetsov, A. M., Medvedev, I. G., Chi, Q., Albrecht, T., Jensen, P. S., & Ulstrup, J. (2008) · Chemical Reviews · doi:10.1021/cr068073+ · Cited by 290
Operando Methods in Electrocatalysis
Yang, Y., Xiong, Y., Zeng, R., Lu, X., Krumov, M., Huang, X., Xu, W., Wang, H., DiSalvo, F. J., Brock, J. D., et al. (2021) · ACS Catalysis · doi:10.1021/acscatal.0c04789 · Cited by 274
Metadata
- Authors
- Schumacher, R.
- Venue
- Angewandte Chemie International Edition in English
- Publisher
- Wiley
- Published
- 1990-04
- Volume
- 29
- Issue
- 4
- Pages
- 329-343
- ISSN
- 0570-0833 (ISSN-L)
- OpenAlex
- W2000163267
- Cited by
- 266
- References
- 13
- FWCI
- 24.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.