The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rational Design of a Fluorescence‐Turn‐On Sensor Array for Phosphates in Blood Serum
Abstract
Getting turned on: An order-of-magnitude fluorescence amplification of simple tripodal sensors has been observed in the presence of phosphate ions. An X-ray structure analysis of one of the complexes (see picture) shows the binding of three phosphate ions, which closely resembles the anionic part of ATP, by the sensor. The sensors were used to generate cross-reactive arrays that can detect anions in human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dhingra, R. (2007) · Archives of Internal Medicine · doi:10.1001/archinte.167.9.879 · Cited by 861
Cited by
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Artificial Receptors for the Recognition of Phosphorylated Molecules
Hargrove, A. E., Nieto, S., Zhang, T., Sessler, J. L., & Anslyn, E. V. (2011) · Chemical Reviews · doi:10.1021/cr100242s · Cited by 649
An indirect approach for anion detection: the displacement strategy and its application
Lou, X., Ou, D., Li, Q., & Li, Z. (2012) · Chemical Communications · doi:10.1039/c2cc33158f · Cited by 272
Metadata
- Authors
- Zyryanov, G. V., Palacios, M. A., & Anzenbacher, P.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2007-10-04
- Volume
- 46
- Issue
- 41
- Pages
- 7849-7852
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2107851804
- Cited by
- 206
- References
- 1
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rational Design of a Fluorescence‐Turn‐On Sensor Array for Phosphates in Blood Serum. https://app.cochat.ai/papers/10.1002/anie.200702611
- The paper
- Zyryanov, G. V., Palacios, M. A., & Anzenbacher, P. (2007). Rational Design of a Fluorescence‐Turn‐On Sensor Array for Phosphates in Blood Serum. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200702611
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.