Computed Tomography in Color: NanoK‐Enhanced Spectral CT Molecular Imaging
Open accessAbstract
Multicolored imaging: A new class of molecular imaging agent has been developed based on low-molecular-weight organically soluble bismuth to detect and quantify intraluminal fibrin presented by ruptured plaque in the context of computed tomography angiograms without calcium interference.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Multicolour CT imaging was applied to visualize thrombi with fibrin-targeted bismuth nanocolloids in rabbit models of atherosclerosis.
“In a study by a different group, multicolour CT imaging was applied to visualize thrombi with fibrin-targeted bismuth nanocolloids in rabbit models of atherosclerosis143.”
From Perspectives and opportunities for nanomedicine in the management of atherosclerosis (2011) · cites this paper as [143]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 23 · Cited by 178
Research works printed but not linked: 1
- [23]a) Lanza GM Wallace KD Fischer SE Christy DH Scott MJ Miller JG Gaffney PJ Wickline SA J Acoust Soc Am 1997 10 391 b) Yu X Song SK Chen J Scott MJ Fuhrhop RJ Hall CS Gaffney PJ Wickline SA Lanza GM Magn Reson Med 2000 44 867 872 11108623
- Authors
- Pan, D., Roessl, E., Schlomka, J., Caruthers, S. D., Senpan, A., Scott, M. J., Allen, J. S., Zhang, H., Hu, G., Gaffney, P. J., Choi, E. T., Rasche, V., Wickline, S. A., Proksa, R., & Lanza, G. M.
- Affiliations
- Washington University in St. Louis (US)
- Philips (Germany) (DE)
- St Thomas' Hospital (GB)
- Universität Ulm (DE)
- Corresponding author
- Pan, Dipanjan
- Lanza, Gregory M.
- ORCID
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2010-11-12
- Volume
- 49
- Issue
- 50
- Pages
- 9635-9639
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- PMC
- PMC3096064
- OpenAlex
- W1997872530
- Cited by
- 178
- References
- 23
- Citations by year
- 2026: 6 · 2025: 4 · 2024: 11 · 2023: 8 · 2022: 11 · 2021: 6 · 2020: 13 · 2019: 11 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 12 · 2014: 22 · 2013: 9 · 2012: 15
- FWCI
- 8.58
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Angewandte Chemie International Edition (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Public Health Service (R01L078631, U54A119342, R01L073646)
- National Heart, Lung, and Blood Institute (HL073646, R01HL073646)
- National Institute of Neurological Disorders and Stroke (R01NS059302)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced X-ray and CT Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
- Keywords
- spectral CT, molecular imaging agents, CT angiography, calcium interference
- MeSH terms
- Animals, Bismuth, Colloids, Color, Contrast Media, Fibrin, Humans, Male, Mice, Inbred BALB C, Rabbits, Thrombosis, Tomography, X-Ray Computed, Mice, Nanoparticles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review