The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Biomimetic Phosphatidylcholine‐Terminated Monolayer Greatly Improves the In Vivo Performance of Electrochemical Aptamer‐Based Sensors
Open accessAbstract
The real‐time monitoring of specific analytes in situ in the living body would greatly advance our understanding of physiology and the development of personalized medicine. Because they are continuous (wash‐free and reagentless) and are able to work in complex media (e.g., undiluted serum), electrochemical aptamer‐based (E‐AB) sensors are promising candidates to fill this role. E‐AB sensors suffer, however, from often‐severe baseline drift when deployed in undiluted whole blood either in vitro or in vivo. We demonstrate that cell‐membrane‐mimicking phosphatidylcholine (PC)‐terminated monolayers improve the performance of E‐AB sensors, reducing the baseline drift from around 70 % to just a few percent after several hours in flowing whole blood in vitro. With this improvement comes the ability to deploy E‐AB sensors directly in situ in the veins of live animals, achieving micromolar precision over many hours without the use of physical barriers or active drift‐correction algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Path to Personalized Medicine
Hamburg, M. A., & Collins, F. S. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006304 · Cited by 1,970
Cited by
Antifouling Strategies for Selective In Vitro and In Vivo Sensing
Jiang, C., Wang, G., Hein, R., Liu, N., Luo, X., & Davis, J. J. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00739 · Cited by 598
Li, S., Zhang, H., Zhu, M., Kuang, Z., Li, X., Xu, F., Miao, S., Zhang, Z., Lou, X., Li, H., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00759 · Cited by 309
Self-citationMayer, M., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00719 · Cited by 300
Mirror-Image L-DNA Aptamers Enable Stable In Vivo Dopamine Sensing
Liu, Y., Jin, Y., Zhu, F., Li, X., Ma, C., Sun, Z., Yao, Y., Song, K., Mao, L., & Jiang, Y. (2026) · Journal of the American Chemical Society · doi:10.1021/jacs.5c22265 · Cited by 17
Metadata
- Authors
- Li, H., Dauphin‐Ducharme, P., Arroyo‐Currás, N., Tran, C. H., Vieira, P. A., Li, S., Shin, C., Somerson, J., Kippin, T. E., & Plaxco, K. W.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2017-03-28
- Volume
- 56
- Issue
- 26
- Pages
- 7492-7495
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2602274463
- Cited by
- 159
- References
- 1
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Biomimetic Phosphatidylcholine‐Terminated Monolayer Greatly Improves the In Vivo Performance of Electrochemical Aptamer‐Based Sensors. https://app.cochat.ai/papers/10.1002/anie.201700748
- The paper
- Li, H., Dauphin‐Ducharme, P., Arroyo‐Currás, N., Tran, C. H., Vieira, P. A., Li, S., Shin, C., Somerson, J., Kippin, T. E., & Plaxco, K. W. (2017). A Biomimetic Phosphatidylcholine‐Terminated Monolayer Greatly Improves the In Vivo Performance of Electrochemical Aptamer‐Based Sensors. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201700748
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.