Novel ultrasonic‐assisted deep eutectic solvent‐based dispersive liquid–liquid microextraction for determination of vanadium in food samples by electrothermal atomic absorption spectrometry: A multivariate study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A green, efficient, simple and sensitive pre‐concentration method has been developed for the determination of vanadium(V) in foodstuffs using deep eutectic solvent–ultrasonic‐assisted dispersive liquid–liquid microextraction. In the developed procedure, the extraction of vanadium(V) was achieved using 2‐hydroxy‐3‐methoxybenzaldehyde thiosemicarbazone as a chelating agent, choline chloride–phenol as extracting solvent and tetrahydrofuran as dispersive solvent. Vanadium(V) concentration was measured using electrothermal atomic absorption spectrometry. Various analytical parameters including pH, type and molar ratio of deep eutectic solvent, ultrasonication time and amount of ligand were studied. A multivariate study was carried out for optimization of the variables. The pre‐concentration factor was calculated as 50. Under optimal conditions, limit of detection, limit of quantification and relative standard deviation were calculated as 0.025 μg l−1, 0.175 μg l−1 and 3.4%, respectively. The accuracy of the procedure was confirmed using certified reference materials and standard addition method. The obtained results confirm adequate recoveries for vanadium(V) (>96%). This technique was fruitfully applied for determination of vanadium in foodstuffs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Choi, Y. H., van Spronsen, J., Dai, Y., Verberne, M., Hollmann, F., Arends, I. W. C. E., Witkamp, G.-J., & Verpoorte, R. (2011) · Plant Physiology · doi:10.1104/pp.111.178426 · Cited by 1,368
Berton, P., Martinis, E. M., & Wuilloud, R. G. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2009.11.094 · Cited by 88
Cited by
Zounr, R. A., Tuzen, M., Deligonul, N., & Khuhawar, M. Y. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.01.167 · Cited by 127
Self-citationAli, J., Tuzen, M., & Kazi, T. G. (2020) · Food Chemistry · doi:10.1016/j.foodchem.2019.125638 · Cited by 74
Self-citationPacheco-Fernández, I., González-Martín, R., e Silva, F. A., Freire, M. G., & Pino, V. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.022 · Cited by 69
Luján, C. E., Lemos, A. A., Oviedo, M. N., Llaver, M., & Wuilloud, R. G. (2024) · Talanta · doi:10.1016/j.talanta.2023.125451 · Cited by 21
Metadata
- Authors
- Zounr, R. A., Tuzen, M., & Khuhawar, M. Y.
- Venue
- Applied Organometallic Chemistry
- Publisher
- Wiley
- Published
- 2017-11-09
- Volume
- 32
- Issue
- 3
- ISSN
- 0268-2605 (ISSN-L)
- 1099-0739
- OpenAlex
- W2767559272
- Cited by
- 30
- References
- 2
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.