Temperature/pH‐sensitive comb‐type graft hydrogels composed of chitosan and poly(N‐isopropylacrylamide)
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Comb‐type graft hydrogels, composed of chitosan and poly(N‐isopropylacrylamide) (PNIPAAm), were prepared to manifest rapid temperature and pH sensitivity. Instead of directly grafting the NIPAAm monomer onto the chitosan chain, semitelechelic PNIPAAm with carboxyl end group was synthesized by radical polymerization using 3‐mercaptopropionic acid as the chain‐transfer agent, and was grafted onto chitosan having amino groups. The comb‐type hydrogels were prepared with two different graft yields and grafting regions, such as surface‐ and bulk‐grafting, and then compared with a chitosan hydrogel. The synthesis of telechelic PNIPAAm and the formation of amide group were confirmed by using FTIR spectroscopy and gel permeation chromatography. Results from the water state and thermal stability revealed that the introduction of the PNIPAAm side chain disturbed the ordered arrangement of the chitosan molecule, resulting in an increase in the equilibrium water content. Comb‐type graft hydrogels showed rapid temperature and pH sensitivity because of the free‐ended PNIPAAm attached to the chitosan main chain and the chitosan amino group itself, respectively. In particular, the surface graft hydrogel maintained its dimension at low pH, although the chitosan main chain was not crosslinked, whereas chitosan and bulk graft hydrogel were dissolved as a result of the coating effect of pH‐independent PNIPAAm. © 2004 Wiley Periodicals, Inc. J Appl Polym Sci 92: 2612–2620, 2004
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of chitin and chitosan applications
Ravi Kumar, M. N. V. (2000) · Reactive and Functional Polymers · doi:10.1016/s1381-5148(00)00038-9 · Cited by 6,009
Cited by
Alginate-Based Biomaterials for Regenerative Medicine Applications
Sun, J., & Tan, H. (2013) · Materials · doi:10.3390/ma6041285 · Cited by 1,361
Kocak, G., Tuncer, C., & Bütün, V. (2017) · Polymer Chemistry · doi:10.1039/c6py01872f · Cited by 1,189
Alves, N. M., & Mano, J. F. (2008) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2008.09.007 · Cited by 804
Injectable, Biodegradable Hydrogels for Tissue Engineering Applications
Tan, H., & Marra, K. G. (2010) · Materials · doi:10.3390/ma3031746 · Cited by 639
Abasalizadeh, F., Moghaddam, S. V., Alizadeh, E., akbari, E., Kashani, E., Fazljou, S. M. B., Torbati, M., & Akbarzadeh, A. (2020) · Journal of Biological Engineering · doi:10.1186/s13036-020-0227-7 · Cited by 608
Hydrogels for tissue engineering and regenerative medicine
Hunt, J. A., Chen, R., van Veen, T., & Bryan, N. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb00775a · Cited by 377
Thermosensitive injectable hyaluronic acid hydrogel for adipose tissue engineering
Tan, H., Ramirez, C. M., Miljkovic, N., Li, H., Rubin, J. P., & Marra, K. G. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.08.058 · Cited by 367
Prabaharan, M., & Mano, J. F. (2006) · Macromolecular Bioscience · doi:10.1002/mabi.200600164 · Cited by 347
PEGylated chitosan derivatives: Synthesis, characterizations and pharmaceutical applications
Casettari, L., Vllasaliu, D., Castagnino, E., Stolnik, S., Howdle, S., & Illum, L. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2011.10.001 · Cited by 232
Metadata
- Authors
- Lee, S. B., Ha, D. I., Cho, S. K., Kim, S. J., & Lee, Y. M.
- Venue
- Journal of Applied Polymer Science
- Publisher
- Wiley
- Published
- 2004-03-11
- Volume
- 92
- Issue
- 4
- Pages
- 2612-2620
- ISSN
- 0021-8995 (ISSN-L)
- 1097-4628
- OpenAlex
- W2012055839
- Cited by
- 107
- References
- 1
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.