Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 336

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Investigation on process parameters of electrospinning system through orthogonal experimental design

Cui, Wenguo, Li, Xiaohong, Zhou, Shaobing, Weng, Jie·2007·Journal of Applied Polymer Science

Abstract

Electrospinning is a very simple and versatile method of creating polymer‐based high‐functional and high‐performance nanofibers. But most of the investigations are not systematic and describe the electrospinning process without quantitative accuracy. Inconsistent and even opposite results have been reported, which has hindered the consistent interpretation of the experiments. Orthogonal experimental method was used to investigate qualitative and quantitative correlations between fiber characteristics (diameters and morphologies) and the processing and materials parameters. Uniform fibers can be obtained without any beads by proper selection of the processing parameters, and a lower glass transition temperature was observed for electrospun fibers than that of native polymer. Results of statistical analysis showed that significant influences were observed for polymer molecular weight and solution concentration on fiber diameters, and there were significant effects of polymer molecular weight, solution concentration, and solvent system on fiber morphologies. Meanwhile, solution concentration and polymer molecular weight, and polymer molecular weight and solvent system had obvious interaction effects. Regression analysis revealed quantitative relations of fiber diameters and beads percent, that is, Y1 = 72.8 X1 − 8.1 X2 + 138.8, Y2 = −3.2 X1 + 0.4 X2 + 60.5, where Y1 is fiber diameter (nm), Y2 beads percent (%), X1 solution concentration (%, w/w), and X2 polymer molecular weight (kDa). Validation test showed that the experimental values of fiber size and beads percent were in good agreement with the calculated ones. Based on these results, optimal conditions could be obtained for predetermined diameters and morphologies for electrospun fibers. © 2006 Wiley Periodicals, Inc. J Appl Polym Sci 103: 3105–3112, 2007

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/app.25464

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

Metadata

Authors
Cui, W., Li, X., Zhou, S., & Weng, J.
Venue
Journal of Applied Polymer Science
Publisher
Wiley
Published
2006-12-12
Volume
103
Issue
5
Pages
3105-3112
ISSN
  • 0021-8995 (ISSN-L)
  • 1097-4628
OpenAlex
W2152500670
Cited by
336
References
17
FWCI
3.32
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.