CoChat

Perspectives: A vital biomechanical model of the endochondral ossification mechanism

Frost, Harold M., Jee, Webster S. S. · 1994 · The Anatomical Record
Cited by 66

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Mechanical usage effects could explain many features of endochondral ossification and related processes. Mineralization of growth plate cartilage could reduce its mechanical strains enough to make its resorption begin and to guide it in space. By removing most of its mineralized vertical septae, resorption could overload the remainder enough to increase woven bone formation on them and construct the primary spongiosa. After it finishes mineralizing, the primary spongiosa could become stiff enough to begin partial disuse in strain terms, so BMU‐based remodeling would begin replacing it with lamellar bone. This would construct the secondary spongiosa. In transferring loads from the growth plate to the cortex, the central metaphyseal spongiosa becomes deloaded. This disuse would make remodeling remove it in the diaphyseal marrow space. Methods: The slow growth of epiphyses and apophyses gives their spongiosas more time to adapt to their loads than the metaphyseal spongiosa beneath faster growing growth plates. Compared to metaphyseal trabeculae, this leads to fewer and thicker epiphyseal trabeculae that turn over more slowly and should persist for life because they carry loads for life. Results: Rapid turnover of metaphyseal cortex in very young subjects could let it strain enough to form woven bone. Increased thickness and slower turnover of this cortex in older subjects could reduce its strains enough to make lamellar bone form there instead. This would compose this cortex mostly of woven bone in the very young and of lamellar bone in adults. Conclusions: This model assigns particular importance to the stiffness and strains of tissues (as distinguished from their strength and stresses), to the relative rates of some processes, and to responses of the skeleton's biologic mechanisms to a tissue's typical largest mechanical strains (as distinguished from their stresses). © 1994 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ar.1092400402

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Frost, H. M., & Jee, W. S. S.
Venue
The Anatomical Record
Publisher
Wiley
Published
1994-12
Volume
240
Issue
4
Pages
435-446
ISSN
  • 0003-276X (ISSN-L)
  • 1097-0185
OpenAlex
W1973727688
Cited by
66
References
3
FWCI
1.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.