Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 194

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

The value of contrast‐enhanced color doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis

Klauser, Andrea, Frauscher, Ferdinand, Schirmer, Michael, Halpern, Ethan, Pallwein, Leo, Herold, Manfred, Helweg, Gernot, ZurNedden, Dieter · 2002 · Arthritis & Rheumatism

Abstract

Objective: A prospective study was performed to assess the usefulness of contrast‐enhanced color Doppler ultrasound (CDUS) in the evaluation of intraarticular vascularization of finger joints in patients with rheumatoid arthritis (RA). Methods: We investigated 198 finger joints in 46 patients with RA, and 80 finger joints in 10 healthy volunteers. Joints with varying levels of clinical activity of inflammation were classified as being active, moderately active, or inactive. CDUS was performed with a high‐frequency multi‐D linear array transducer. A microbubble‐based ultrasound (US) contrast agent (Levovist; Schering, Berlin, Germany) was intravenously infused. Doppler findings were rated on the basis of both unenhanced and contrast‐enhanced CDUS images. Results: Healthy joints showed no intraarticular vascularization on either unenhanced or contrast‐enhanced CDUS. Unenhanced CDUS detected intraarticular vascularization in 7 (8%) of 83 inactive joints, in 31 (52%) of 60 moderately active joints, and in 32 (58%) of 55 active joints. Contrast‐enhanced CDUS detected intraarticular vascularization in 41 (49%) of 83 joints with inactive RA, in 59 (98%) of 60 joints with moderately active RA, and in all 55 joints with active RA. Detection of intraarticular vascularization was improved by administration of the microbubble‐based US contrast agent (P < 0.001). Contrast‐enhanced CDUS demonstrated differences in intraarticular vascularization between joints with inactive RA and those with active RA (P < 0.001), between joints with inactive RA and those with moderately active RA (P < 0.001), and between joints with moderately active RA and those with active RA (P < 0.001). Conclusion: The use of a microbubble‐based US contrast agent significantly improved the detection of intraarticular vascularization in the finger joints of patients with RA. This technique seems to be a useful adjunct in the assessment of disease activity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/art.10136

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 194

Metadata

Authors
Klauser, A., Frauscher, F., Schirmer, M., Halpern, E., Pallwein, L., Herold, M., Helweg, G., & ZurNedden, D.
Venue
Arthritis & Rheumatism
Publisher
Wiley
Published
2002-03
Volume
46
Issue
3
Pages
647-653
ISSN
  • 0004-3591 (ISSN-L)
  • 1529-0131
OpenAlex
W1987367577
Cited by
194
References
2
FWCI
9.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The value of contrast‐enhanced color doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis. https://app.cochat.ai/papers/10.1002/art.10136
The paper
Klauser, A., Frauscher, F., Schirmer, M., Halpern, E., Pallwein, L., Herold, M., Helweg, G., & ZurNedden, D. (2002). The value of contrast‐enhanced color doppler ultrasound in the detection of vascularization of finger joints in patients with rheumatoid arthritis. Arthritis & Rheumatism. https://doi.org/10.1002/art.10136

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.