Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: Comparison of standing anteroposterior and Lyon Schuss views
Abstract
Objective: To evaluate progression of joint space narrowing in radiographs of osteoarthritic (OA) knees imaged in both the standing anteroposterior (AP) and the Lyon schuss positions, using alternative methods to measure joint space width (JSW). Methods: Standing AP (extended view) and Lyon schuss (posteroanterior [PA] view, with 20–30° of flexion) radiographic images of 58 OA knees were obtained twice (at baseline and 2 years later). With both methods, fluoroscopy was used to align the anterior and posterior margins of the medial or lateral tibial plateau with the central x‐ray beam. Minimum JSW, mean JSW, and joint space area (JSA) of the medial or lateral femorotibial joint space were measured using a new digital image analysis system. The effects of knee flexion versus extension and parallel versus nonparallel tibial plateau alignment were evaluated with respect to the reproducibility of JSW in repeated examinations (intraclass correlation coefficient [ICC]), the mean of within‐knee standard deviations of repeated measurements (SD m), and the sensitivity to changes in JSW in serial radiographs (standardized response mean [SRM]). Results: The performance of the new software, as assessed by the reproducibility of repeated measurements of minimum JSW on the same image, was excellent in both the standing AP (ICC = 0.98) and Lyon schuss radiographs (2 SD m = 0.5 mm, ICC = 0.98). The reproducibility in different radiographs of the same knee was not evaluated. However, over 2 years, the mean (± SD) decrease in the minimum JSW of OA knees was 0.17 ± 0.75 mm in standing AP radiographs (P not significant) and 0.24 ± 0.50 mm in Lyon schuss views (P = 0.007), with SRMs of 0.23 and 0.48, respectively. The quality of alignment of the tibial plateau was satisfactory (<1 mm between anterior and posterior margins of the medial tibial plateau) in 66% of the pairs of Lyon schuss radiographs and in 57% of the pairs of standing AP radiographs. In the Lyon schuss radiographs, SRM was highly dependent on tibial plateau alignment. Minimum JSW was more sensitive to change than was mean JSW or JSA, in paired Lyon schuss radiographs that exhibited satisfactory alignment. Conclusion: Compared with the standing AP radiograph, PA imaging of the knee in 20–30° flexion (the schuss position) increases the reproducibility of radiographic JSW measurements in OA knees and the sensitivity to change in JSW in serial radiographs. Sensitivity to change in minimum JSW is notably increased by aligning the medial tibial plateau with the central x‐ray beam in the Lyon schuss radiograph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Sakellariou, G., Conaghan, P. G., Zhang, W., Bijlsma, J. W. J., Boyesen, P., D'Agostino, M. A., Doherty, M., Fodor, D., Kloppenburg, M., Miese, F., et al. (2017) · Annals of the Rheumatic Diseases · doi:10.1136/annrheumdis-2016-210815 · Cited by 280
Chondroitins 4 and 6 sulfate in osteoarthritis of the knee: A randomized, controlled trial
Michel, B. A., Stucki, G., Frey, D., De Vathaire, F., Vignon, E., Bruehlmann, P., & Uebelhart, D. (2005) · Arthritis & Rheumatism · doi:10.1002/art.20867 · Cited by 261
Self-citationRaynauld, J.-P., Martel-Pelletier, J., Berthiaume, M.-J., Beaudoin, G., Choquette, D., Haraoui, B., Tannenbaum, H., Meyer, J. M., Beary, J. F., Cline, G. A., et al. (2005) · Arthritis Research & Therapy · doi:10.1186/ar1875 · Cited by 259
A new marker for osteoarthritis: Cross‐sectional and longitudinal approach
Reijman, M., Hazes, J. M. W., Bierma‐Zeinstra, S. M. A., Koes, B. W., Christgau, S., Christiansen, C., Uitterlinden, A. G., & Pols, H. A. P. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20332 · Cited by 255
Metadata
- Authors
- Vignon, E., Piperno, M., Le Graverand, M. H., Mazzuca, S. A., Brandt, K. D., Mathieu, P., Favret, H., Vignon, M., Merle‐Vincent, F., & Conrozier, T.
- Venue
- Arthritis & Rheumatism
- Publisher
- Wiley
- Published
- 2003-02
- Volume
- 48
- Issue
- 2
- Pages
- 378-384
- ISSN
- 0004-3591 (ISSN-L)
- 1529-0131
- OpenAlex
- W2144479507
- Cited by
- 179
- References
- 1
- FWCI
- 6.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: Comparison of standing anteroposterior and Lyon Schuss views. https://app.cochat.ai/papers/10.1002/art.10773
- The paper
- Vignon, E., Piperno, M., Le Graverand, M. H., Mazzuca, S. A., Brandt, K. D., Mathieu, P., Favret, H., Vignon, M., Merle‐Vincent, F., & Conrozier, T. (2003). Measurement of radiographic joint space width in the tibiofemoral compartment of the osteoarthritic knee: Comparison of standing anteroposterior and Lyon Schuss views. Arthritis & Rheumatism. https://doi.org/10.1002/art.10773
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.