The DOI matches its Crossref record.
Does cartilage compliance reduce skeletal impact loads?. the relative force‐attenuating properties of articular cartilage, synovial fluid, periarticular soft tissues and bone
Abstract
Joint wear is related to the pressure exerted at the articular cartilage interface. The largest loads an animal joint experiences in life will be brief and will result from impact. Compliance in the system will decrease the peak value of such impulsive loadings at the expense, probably unimportant, of increasing their duration. The ability of synovial fluid, supporting bone and periarticular soft tissues to provide this compliance and attenuate peak forces might spare the articular cartilage and prevent wear. Measurements were made of the relative attenuation of longitudinally applied, external impulsive force by these major joint elements of adult bovine interphalangeal joints. The effect of the various elements, independently, upon the over‐all compliance of the joint was measured in nonimpulsive experiments and found to correlate quite well with their ability to reduce the peak load in the impulsive experiments. Only the periarticular soft tissues (capsule, ligaments and synovial tissue) and bone have significant force‐attenuating properties. Articular cartilage and synovial fluid have little effect. These results support the contention that the integrity of bone could well be important in prolonging joint life.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Response of joints to impact loading — III
Radin, E. L., Parker, H. G., Pugh, J. W., Steinberg, R. S., Paul, I. L., & Rose, R. M. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90037-7 · Cited by 619
Self-citationThe basic science of the subchondral bone
Madry, H., van Dijk, C. N., & Mueller‐Gerbl, M. (2010) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-010-1054-z · Cited by 615
ROLE OF MECHANICAL FACTORS IN PATHOGENESIS OF PRIMARY OSTEOARTHRITIS
Radin, E., Paul, I., & Rose, R. (1972) · The Lancet · doi:10.1016/s0140-6736(72)90179-1 · Cited by 593
Self-citationReduced quadriceps strength relative to body weight: A risk factor for knee osteoarthritis in women?
Slemenda, C., Heilman, D. K., Brandt, K. D., Katz, B. P., Mazzuca, S. A., Braunstein, E. M., & Byrd, D. (1998) · Arthritis & Rheumatism · doi:10.1002/1529-0131(199811)41:11<1951::aid-art9>3.0.co;2-9 · Cited by 591
Etiopathogenesis of Osteoarthritis
Brandt, K. D., Dieppe, P., & Radin, E. (2009) · Medical Clinics of North America · doi:10.1016/j.mcna.2008.08.009 · Cited by 530
Self-citation
Metadata
- Authors
- Radin, E. L., & Paul, I. L.
- Venue
- Arthritis & Rheumatism
- Publisher
- Wiley
- Published
- 1970-03
- Volume
- 13
- Issue
- 2
- Pages
- 139-144
- ISSN
- 0004-3591 (ISSN-L)
- 1529-0131
- OpenAlex
- W2116339731
- Cited by
- 226
- References
- 0
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Does cartilage compliance reduce skeletal impact loads?. the relative force‐attenuating properties of articular cartilage, synovial fluid, periarticular soft tissues and bone. https://app.cochat.ai/papers/10.1002/art.1780130206
- The paper
- Radin, E. L., & Paul, I. L. (1970). Does cartilage compliance reduce skeletal impact loads?. the relative force‐attenuating properties of articular cartilage, synovial fluid, periarticular soft tissues and bone. Arthritis & Rheumatism. https://doi.org/10.1002/art.1780130206
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.