Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Reliability of the knee examination in osteoarthritis: Effect of standardization

Cibere, Jolanda, Bellamy, Nicholas, Thorne, Anona, Esdaile, John M., McGorm, Kelly J., Chalmers, Andrew, Huang, Simon, Peloso, Paul, Shojania, Kam, Singer, Joel, Wong, Hubert, Kopec, Jacek · 2004 · Arthritis & Rheumatism

Abstract

Objective: To assess the reliability of physical examination of the osteoarthritic (OA) knee by rheumatologists, and to evaluate the benefits of standardization. Methods: Forty‐two physical signs and techniques were evaluated using a 6 × 6 Latin square design. Patients with mild to severe knee OA, based on physical and radiographic signs, were examined in random order prior to and following standardization of techniques. For those signs with dichotomous scales, agreement among the rheumatologists was calculated as the prevalence‐adjusted bias‐adjusted kappa (PABAK), while for the signs with continuous and ordinal scales, a reliability coefficient (R c) was calculated using analysis of variance. A PABAK of >0.60 and an R c of >0.80 were considered to indicate adequate reliability. Results: Adequate poststandardization reliability was achieved for 30 of 42 physical signs/techniques (71%). The most highly reliable signs identified by physical examination of the OA knee included alignment by goniometer (R c = 0.99), bony swelling (R c = 0.97), general passive crepitus (R c = 0.96), gait by inspection (PABAK = 0.78), effusion bulge sign (R c = 0.97), quadriceps atrophy (R c = 0.97), medial tibiofemoral tenderness (R c = 0.94), lateral tibiofemoral tenderness (R c = 0.85), patellofemoral tenderness by grind test (R c = 0.94), and flexion contracture (R c = 0.95). The standardization process resulted in substantial improvements in reliability for evaluation of a number of physical signs, although for some signs, minimal or no effect of standardization was noted. After standardization, warmth (PABAK = 0.14), medial instability at 30° flexion (PABAK = 0.02), and lateral instability at 30° flexion (PABAK = 0.34) were the only 3 signs that were highly unreliable. Conclusion: With the exception of physical examinations for instability, a comprehensive knee examination can be performed with adequate reliability. Standardization further improves the reliability for some physical signs and techniques. The application of these findings to future OA studies will contribute to improved outcome assessments in OA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/art.20025

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 204

Metadata

Authors
Cibere, J., Bellamy, N., Thorne, A., Esdaile, J. M., McGorm, K. J., Chalmers, A., Huang, S., Peloso, P., Shojania, K., Singer, J., Wong, H., & Kopec, J.
Venue
Arthritis & Rheumatism
Publisher
Wiley
Published
2004-02
Volume
50
Issue
2
Pages
458-468
ISSN
  • 0004-3591 (ISSN-L)
  • 1529-0131
OpenAlex
W2086968448
Cited by
204
References
2
FWCI
6.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.