Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Validation and reproducibility of ultrasonography in the detection of synovitis in the knee: A comparison with arthroscopy and clinical examination

Karim, Z., Wakefield, R. J., Quinn, M., Conaghan, P. G., Brown, A. K., Veale, D. J., Connor, P. O', Reece, R., Emery, P.·2004·Arthritis & Rheumatism

Abstract

Objective: Accurate detection of synovitis is important in both the diagnosis and outcome assessment of arthritis. This study was undertaken to assess the validity and reproducibility of ultrasonography (US) as a means of detecting synovitis in the knee, by comparing US findings with findings of arthroscopy and clinical examination. Methods: Sixty consecutive patients with knee pain due to various arthritides had a clinical examination and US of their knee performed immediately prior to arthroscopy. All 3 assessments were performed by different clinicians who were blinded to the results obtained with the other modalities. US and clinical examination were compared with arthroscopically detected synovitis as the gold standard. Data from a subset of patients were used for calculating the inter‐ and intrareader reproducibility of US results, using a standard dichotomous (absence/presence of synovitis) as well as a graded (absence/grade of synovitis) scoring system. Results: With the use of arthroscopy as the gold standard, US had a higher sensitivity (98% versus 85%), specificity (88% versus 25%), accuracy (97% versus 77%), positive predictive value (98% versus 88%), and negative predictive value (88% versus 20%) compared with clinical examination. The Cohen kappa values for inter‐ and intrareader reproducibility of US for distinguishing between presence and absence of synovitis were 0.71 and 0.85, respectively (P < 0.05 for both). The weighted kappa values for distinguishing grade of synovitis were 0.65 for inter‐ and 0.74 for intrareader reproducibility. The kappa value for intrareader reproducibility of arthroscopy results was 0.88. Conclusion: Ultrasonography is a valid and reproducible technique for detecting synovitis in the knee, and is more accurate than clinical examination. It may be valuable as a tool in studies investigating pain, diagnosis, and treatment response in knee arthritis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/art.20054

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 241

Metadata

Authors
Karim, Z., Wakefield, R. J., Quinn, M., Conaghan, P. G., Brown, A. K., Veale, D. J., Connor, P. O., Reece, R., & Emery, P.
Venue
Arthritis & Rheumatism
Publisher
Wiley
Published
2004-02
Volume
50
Issue
2
Pages
387-394
ISSN
  • 0004-3591 (ISSN-L)
  • 1529-0131
OpenAlex
W2015143860
Cited by
241
References
1
FWCI
8.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation and reproducibility of ultrasonography in the detection of synovitis in the knee: A comparison with arthroscopy and clinical examination. https://app.cochat.ai/papers/10.1002/art.20054
The paper
Karim, Z., Wakefield, R. J., Quinn, M., Conaghan, P. G., Brown, A. K., Veale, D. J., Connor, P. O., Reece, R., & Emery, P. (2004). Validation and reproducibility of ultrasonography in the detection of synovitis in the knee: A comparison with arthroscopy and clinical examination. Arthritis & Rheumatism. https://doi.org/10.1002/art.20054

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.